Effectiveness and usability of Scanning Wizard software: a tool for enhancing switch scanning.

Disabil Rehabil Assist Technol

b Department of Occupational Therapy , Duquesne University, Pittsburgh , PA , USA.

Published: February 2019

Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study evaluated Scanning Wizard's effectiveness and usability. Ten people who use switch scanning and ten practitioners used Scanning Wizard in the initial session. Usability was high, based on survey responses averaging over 4.5 out of 5, and qualitative feedback was very positive. Five switch users were able to complete the multi-week protocol, using settings on their own scanning system that were recommended from the Scanning Wizard session. Using these revised settings, text entry rates improved by an average of 71%, ranging from 29% to 172% improvement. Results suggest that Scanning Wizard is a useful tool for improving the configuration of scanning systems for people who use switch scanning to communicate. Implications for Rehabilitation Some individuals with severe physical impairments use switch scanning for spoken and written communication. Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study demonstrated high usability of Scanning Wizard (with 10 switch userpractitioner teams) and increased text entry rate by an average of 71% (for five switch users). Results suggest that Scanning Wizard is a useful tool for improving the configuration of scanning systems for people who use switch scanning to communicate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5967995PMC
http://dx.doi.org/10.1080/17483107.2017.1406998DOI Listing

Publication Analysis

Top Keywords

scanning wizard
32
switch scanning
28
scanning
21
wizard software
12
scanning system
12
people switch
12
switch
10
effectiveness usability
8
usability scanning
8
wizard
8

Similar Publications

Objective: The aim of this study was to evaluate the bending and torsional resistance of the following instruments: Mtwo 25/.07 (MT - VDW, Munich, Germany), Navigator W-XN 25.07 (WXN - Wizard Navigator, Medin, Nové Město na Moravě, Czech Republic), ProTaper Universal SX 19/.

View Article and Find Full Text PDF

Effectiveness and usability of Scanning Wizard software: a tool for enhancing switch scanning.

Disabil Rehabil Assist Technol

February 2019

b Department of Occupational Therapy , Duquesne University, Pittsburgh , PA , USA.

Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study evaluated Scanning Wizard's effectiveness and usability. Ten people who use switch scanning and ten practitioners used Scanning Wizard in the initial session.

View Article and Find Full Text PDF

Diagnostic value of using multiplanar reformation images: Case report for rare endotracheal hamartomas.

Medicine (Baltimore)

October 2017

Department of Radiology, Panyu Central Hospital of Guangzhou, Guangzhou, P.R. China Department of Radiology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, P.R. China Department of Radiology, Keck Medical Center of USC, Los Angeles, CA.

Rationale: Pulmonary hamartomas are the most common benign tumor of the lung. Two types of pathologically similar hamartomas exist based on their location. These tumors have a low incidence, are rarely reported and frequently misdiagnosed because of lack of familiarity and/or understanding concerning their imaging features.

View Article and Find Full Text PDF

Scanning Wizard software helps scanning users improve the setup of their switch and scanning system. This study is evaluating Scanning Wizard's effectiveness, with nine people who use single-switch scanning participating to date. Text entry rates have improved by an average of 71%, ranging from 29 to 172% improvement.

View Article and Find Full Text PDF

Objectives: This study evaluated the effect of sodium hypochlorite (NaOCl) irrigation with or without surfactants on the bond strength of an epoxy-based sealer to the root canal dentin.

Materials And Methods: Eighty decoronated single-rooted human mandibular premolars were instrumented using the rotary system. The roots were subsequently rinsed with 5 ml 17 % EDTA for 1 min and then randomly divided into 3 test groups (n = 20) and 1 control group (n = 20) according to the type of irrigation with experimental 5 % NaOCl (Wizard, RehberKimya, Istanbul, Turkey) solutions: Group 1: NaOCl-0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!