Bioelectric impedance analysis (BIA) devices are commonly used to estimate percent body fat (%fat), although validation of their accuracy varies widely. The purpose of this study was to assess the validity of four commonly used BIA devices compared to dual-energy X-ray absorptiometry (DXA). College-aged men (n = 29, age = 19.7 ± 1.2 y, weight = 76.9 ± 12.5 kg) and women (n = 31, age = 20.5 ± 0.8 y, weight = 61.5 ± 9.2 kg) were evaluated for %fat using four single-frequency (50 mHz) BIA devices and DXA. A gender × device repeated measures ANOVA indicated some less expensive BIA devices produced %fat values that were not significantly different from DXA. A thumb-to-thumb BIA device produced the closest values in men (21.9 ± 6.6%) and women (32.1 ± 5.3%) compared to DXA (20.6 ± 6.1% and 30.3 ± 5.4%, respectively). The two more expensive BIA devices significantly underestimated in men (14.7 ± 5.8% and 17.0 ± 5.6%) and women (23.3 ± 4.2% and 23.3 ± 4.2%) compared to DXA. Interclass correlation coefficients with DXA were higher for the more expensive devices in men (ICC = 0.899 and 0.958) than the less expensive devices (ICC = 0.681 and 0.730). In women, all BIA devices showed moderate correlations with DXA (ICC = 0.537 to 0.658). Despite the convenience of simple BIA devices, their use in estimating body composition in young men and women might be questionable due to large variations in the differences between DXA and each device in this study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5685086 | PMC |
Case Reports Plast Surg Hand Surg
January 2025
Department of Neuroscience, Mental Health and Sense Organs (NESMOS), Sant' Andrea Hospital, Rome, Italy.
Background: Breast Implant Associated Anaplastic Large Cell Lymphoma (BIA-ALCL) is a haematological malignancy which may occur in patients with textured breast implant history. While typically diagnosed at an early stage with good prognosis, it may present with local residual disease due to incomplete surgical excision.
Case Presentation: We describe the case of a 42 year-old woman with a history of bilateral breast augmentation for cosmetic purposes 21 years prior, who developed recurring seroma of the left side.
Nutrients
December 2024
Aladina-MGU-Regional Human Milk Bank, 12 de Octubre University Hospital, 28041 Madrid, Spain.
: To obtain bioelectrical data to assess nutritional status for extremely low-birth-weight (ELBW) infants upon reaching term-corrected age. : A descriptive, observational, prospective, and single-center study, which included ELBW preterm infants was performed. The study variables collected were gestational age, sex, and anthropometry at birth and at term-corrected age.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Invasive Cardiology, Medical University of Białystok, 15-089 Białystok, Poland.
Sudden cardiac death (SCD) remains a major global health concern and represents one of the most common causes of mortality due to cardiovascular diseases. The wearable cardioverter-defibrillator (WCD) is an innovative, non-invasive medical device designed to provide continuous heart monitoring and immediate defibrillation in patients at risk for SCD. The study aimed to assess the efficacy of WCD usage in patients awaiting decision on therapy with implantable cardioverter-defibrillators (ICDs).
View Article and Find Full Text PDFJ Electromyogr Kinesiol
December 2024
Department of Biomedical Sciences for Health, Università degli Studi di Milano, via G. Colombo 71, 20133 Milan, Italy.
This study investigated the intra-day and inter-day reliability of electrical impedance myography (EIM) components and explored sex and regional differences in healthy adults' anterior thigh muscles. Using a multifrequency device, impedance values across various frequencies, alongside 50-kHz resistance (R), reactance (Xc), and phase angle (PhA) were assessed in both sexes and at whole anterior thigh, proximal and distal regions. Findings revealed excellent reliability (ICC > 0.
View Article and Find Full Text PDFAesthetic Plast Surg
January 2025
Directorate General of Medical Devices and Pharmaceutical service of the Italian Ministry of Health, Via Ribotta 5, 00144, Rome, Italy.
Level of Evidence III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.