A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of nicotine on machined- and anodized-surface implants. Histometric analysis. | LitMetric

Background: The nicotine may generate a influence on bone repair and longevity of dental implants. This fact makes studies to improve the surface of the implants are constantly conducted. This study aimed to evaluate the influence of subcutaneous nicotine injection in the osseointegration process on different implant surfaces, through histomorphometric analysis.

Material And Methods: Therefore, twenty-two male rabbits were randomly distributed into two groups according to the subcutaneous injections: (1) nicotine, 3 mg/day/kg and (2) 0.9% NaCI, 3 mL/day/kg, three times a day. Subgroups were then designated - machined and anodized dental implants were installed in the right and left tibia bones, respectively. The animals were subjected to euthanasia after periods of eight weeks for histomorphometric analysis. The bone samples with implants were removed and the routine histological processing was performed. Next, the images obtained from the blades were evaluated by the Image Tool™ software, assessing the osseointegrated areas of implants (BIC), in pixels. Data obtained were subjected to intergroup statistical analysis through the Kruskal-Wallis non-parametric test (α=5%).

Results: The test result showed no statistically significant difference among the groups studied (=0.446).

Conclusions: Based on the methodology studied, it is concluded that the daily application of low doses of nicotine did not interfere with the osseointegration of machined and anodized implants. Bone-implant interface, implants, osseointegration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5694149PMC
http://dx.doi.org/10.4317/jced.54127DOI Listing

Publication Analysis

Top Keywords

implants
8
dental implants
8
machined anodized
8
influence nicotine
4
nicotine machined-
4
machined- anodized-surface
4
anodized-surface implants
4
implants histometric
4
histometric analysis
4
analysis background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!