Objective: To evaluate the accuracy of raw-data-based effective atomic number (Z) values and monochromatic CT numbers for contrast material of varying iodine concentrations, obtained using dual-energy CT.
Methods: We used a tissue characterization phantom and varying concentrations of iodinated contrast medium. A comparison between the theoretical values of Z and that provided by the manufacturer was performed. The measured and theoretical monochromatic CT numbers at 40-130 keV were compared.
Results: The average difference between the Z values of lung (inhale) inserts in the tissue characterization phantom was 81.3% and the average Z difference was within 8.4%. The average difference between the Z values of the varying concentrations of iodinated contrast medium was within 11.2%. For the varying concentrations of iodinated contrast medium, the differences between the measured and theoretical monochromatic CT values increased with decreasing monochromatic energy. The Z and monochromatic CT numbers in the tissue characterization phantom were reasonably accurate.
Conclusion: The accuracy of the raw-data-based Z values was higher than that of image-based Z values in the tissue-equivalent phantom. The accuracy of Z values in the contrast medium was in good agreement within the maximum SD found in the iodine concentration range of clinical dynamic CT imaging. Moreover, the optimum monochromatic energy for human tissue and iodinated contrast medium was found to be 70 keV. Advances in knowledge: The accuracy of the Z values and monochromatic CT numbers of the contrast medium created by raw-data-based, dual-energy CT could be sufficient in clinical conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5965787 | PMC |
http://dx.doi.org/10.1259/bjr.20170524 | DOI Listing |
J Coll Physicians Surg Pak
January 2025
Department of Microbiology, Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan.
Objective: To evaluate Chicago Sky Blue (CSB) stain, Calcofluor white (CW) stain, and Potassium Hydroxide (KOH) mount for rapid diagnosis of dermatomycosis, using fungal culture as the gold standard.
Study Design: Cross-sectional analytical study. Place and Duration of the Study: This study was conducted in the Department of Microbiology, Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan, from July 2023 to February 2024.
Sci Rep
January 2025
Department of Neurosurgery, University Hospital Tübingen, Tübingen, Germany.
To compare 1D (linear) tumor volume calculations and classification systems with 3D-segmented volumetric analysis (SVA), focusing specifically on their effectiveness in the evaluation and management of NF2-associated vestibular schwannomas (VS). VS were clinically followed every 6 months with cranial, thin-sliced (< 3 mm) MRI. We retrospectively reviewed and used T1-weighted post-contrast enhanced (gadolinium) images for both SVA and linear measurements.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:
Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Am Fam Physician
January 2025
University of Florida College of Medicine, Gainesville.
Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!