Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We have designed a pumpless acoustofluidic device for the concentration and separation of different sized particles inside a single-layered straight polydimethylsiloxane (PDMS) microfluidic channel. The proposed device comprises two parallel interdigitated transducers (IDTs) positioned underneath the PDMS microchannel. The IDTs produce high-frequency surface acoustic waves that generate semipermeable virtual acoustic radiation force field walls that selectively trap and concentrate larger particles at different locations inside the microchannel and allow the smaller particles to pass through the acoustic filter. The performance of the acoustofluidic device was first characterized by injecting into the microchannel a uniform flow of suspended 9.9 μm diameter particles with various initial concentrations (as low as 10 particles/mL) using a syringe pump. The particles were trapped with ∼100% efficiency by a single IDT actuated at 73 MHz. The acoustofluidic platform was used to demonstrate the pumpless separation of 12.0, 4.8, and 2.1 μm microparticles by trapping the 12 and 4.8 μm particles using the two IDTs actuated at 73 and 140 MHz, respectively. However, most of the 2.1 μm particles flowed over the IDTs unaffected. The acoustofluidic device was capable of rapidly processing a large volume of sample fluid pumped through the microchannel using an external syringe pump. A small volume of the sample fluid was processed through the device using a capillary flow and a hydrodynamic pressure difference that did not require an external pumping device.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.7b04014 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!