A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Pseudophacic additive lenses]. | LitMetric

[Pseudophacic additive lenses].

Klin Monbl Augenheilkd

Published: December 2017

Implantation of artificial intraocular lenses (IOL) after cataract removal today represents the standard of care in the field of anterior segment surgery. In refractive lens exchange cases the natural lens is replaced by an IOL to correct different types of refractive situations. In the majority of the operations the refractive result is satisfying with only few deviations from target refraction.But daily practice reveals some outliers from the intended corrections with the need for further refractive enhancements, respectively. Especially odd eyes with short or long axial length, corneal astigmatism, ceratoconus or after corneal laser vision correction are more or less candidates for refractive surprises. Laser corneal surgery and additional intraocular implants are both established surgical approaches to achieve this goal in pseudophacic eyes. In paediatric cataract surgery for congenital cataracts implantation of add-on lenses can be helpful to adjust refraction according to eyeball development and prevent amblyopia.This article presents an overview about currently available implants and techniques using additional lenses to correct residual refractive errors. Furthermore, new implants for special indications like macular degeneration are addressed. A thorough evaluation of risk and benefit for each patient group and materials used are provided.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0043-120095DOI Listing

Publication Analysis

Top Keywords

refractive
6
[pseudophacic additive
4
additive lenses]
4
lenses] implantation
4
implantation artificial
4
artificial intraocular
4
intraocular lenses
4
lenses iol
4
iol cataract
4
cataract removal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!