Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 998
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3138
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Patients on venoarterial or venovenous extracorporeal membrane oxygenation (ECMO) support may require venoarterial-venous (VAV-ECMO) configuration during follow-up. We report 12 cases of VAV-ECMO with significant outflow steal.
Methods: Between October 2014 and November 2016, a total of 97 patients (56.6 ± 12.0 years; 59 men/38 women; body surface area 1.84 ± 0.36 m2) were supported with venoarterial ECMO (n = 85) or venovenous ECMO (n = 12). Among the 97 patients, 12 patients (age 61.5 ± 3.5 years; 8 men/4 women; body surface area 1.8 ± 0.8 m2) required hybrid use of VAV-ECMO. Control and monitoring of flow ratios in supplying cannulae using flow sensors were performed, and occluder devices were used according to patient requirements to achieve optimum haemodynamics and oxygenation.
Results: Among the 85 venoarterial ECMO-supported patients, Harlequin syndrome was detected in 9 cases (10.6%) who required switching to VAV-ECMO. Among the 12 patients, 3 (25%) patients required VAV-ECMO while on venovenous ECMO support as a result of initial respiratory failure subsequently developed cardiac decompensation. Mean duration of VAV-ECMO support was 6.4 ± 1.8 days. Overall, on VAV-ECMO support, 70.0 ± 4.6% of blood flow was detected within the supplying right internal jugular vein cannula as a result of lower afterload in venous system. We partially occluded the internal jugular vein cannula and directed flow to the common femoral artery. After adjustment, 34.3 ± 7.4% flow was directed to internal jugular vein and 65.6 ± 7.4% to common femoral artery.
Conclusions: Non-invasive monitoring of flow rates within the supplying cannulae of VAV-ECMO and the use of partial occlusion for venous-supplying cannula enable individualized patient management and effective weaning from VAV-ECMO.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/icvts/ivx259 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!