Objective: To demonstrate robot-assisted ureterolysis and buccal mucosal graft (BMG) ureteroplasty for the management of a complex, long recurrent ureteral stricture developing after ureterolysis, and also to demonstrate the use of near-infrared fluorescence (NIRF) imaging and intraoperative ureteroscopy during this procedure.

Methods: A 58-year-old man with a history of cabergoline treatment and a cardiac catheterization through the left groin presented with left flank pain and hydronephrosis. A computed tomography scan showed extensive fibrosis around the ureter and a ureteral stricture close to a tortuous left external iliac artery. A computed tomography-guided biopsy showed a benign fibrous tissue around the stricture with no increase in IgG4-expressing plasma cells. A robot-assisted ureterolysis with an omental wrap was performed. One year after the ureterolysis, the patient developed a recurrent ureteral stricture. Retrograde ureterogram showed a long, 6-cm stricture in the upper ureter. For the robotic ureteroplasty, the patient was placed in modified lateral position with port placement similar to the left pyeloplasty. Intraoperative flexible ureteroscopy and NIRF were used to define the distal extent of the stricture. For this, the ureteroscope was advanced until the stricture, and transilluminance of light from the ureteroscope was seen from the robotic camera using Firefly. Ureteral stricture was incised along its length over the ureteroscope. Two BMGs were harvested and sown together to obtain a longer graft. The graft was minimally defatted and brought in the abdomen through one of the ports. The composite graft was then sutured with 4-0 PDS as an onlay graft with the mucosal side facing toward the lumen of the ureter. Ureteroscopy was used to confirm patency, followed by stent placement. NIRF was used to confirm the viability of the ureter and the surrounding tissue. The omental flap was then harvested using a vessel sealer, fixed to the psoas fascia beneath the ureter, and then wrapped over the reconstructed ureter. The omental flap was also tacked to the side of the BMG with a suture to promote blood supply.

Results: The procedure was uncomplicated with an operative time of 280 minutes, an estimated blood loss of 75 mL, and an uneventful hospital stay. MAG3 Renal scan after 3 and 6 months of surgery showed no recurrence or obstruction.

Conclusion: Despite the limitation of being a single case with only a 6-month follow-up, our report shows that robot-assisted BMG is a safe option for the reconstruction of long upper ureteral strictures. This procedure may be a less morbid alternative to an autotransplant and ileal ureter in these patients. However, outcomes need to be studied in a larger series with a longer follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2017.06.037DOI Listing

Publication Analysis

Top Keywords

ureteral stricture
20
stricture
9
buccal mucosal
8
mucosal graft
8
robot-assisted ureterolysis
8
recurrent ureteral
8
omental flap
8
ureter
7
graft
6
ureteral
6

Similar Publications

Purpose: To evaluate the feasibility of robot-assisted ureteral reconstruction as a minimally invasive alternative to open surgery for managing ureteric complications in transplanted kidneys.

Materials And Methods: From January 2020 to December 2023, robot-assisted ureteral reconstruction was performed on fifteen kidney transplant patients with vesicoureteral reflux (VUR) or ureteral stricture who had previously failed endoscopic treatments.

Results: Twelve females and three males, with a mean age of 48.

View Article and Find Full Text PDF

Background: We aimed to assess the rates of urethral stricture in transplant recipients, analyse patients with urethral strictures and present the posttreatment follow-up outcomes.

Methods: Between 2004 and 2023, a retrospective examination was conducted on kidney transplant recipients who underwent removal of ureteral catheters through retrograde cystoscopy at our facility or referred from external centres. The collected data encompassed patient demographics, pre- and posttransplant maximum urinary flow rate, specifics of stenosis, surgical interventions and outcomes from a 1-year follow-up.

View Article and Find Full Text PDF

We present a method of internalization of nephroureteral stents to internalized ureteral stents in a patient with an ileac conduit urostomy with radiation-induced ureteral strictures, and recurrent urinary tract infections (UTIs). This technique is applicable to patients requiring internalization of nephroureteral stents in the setting of an ileal conduit, emphasizing patient consent, preparation, position, imaging guidance, and antibiotic prophylaxis. The successful application of this technique offers a practical solution for managing recurrent UTIs in patients with similar medical histories, providing both clinical and procedural insights.

View Article and Find Full Text PDF

Introduction: Auto-expandable ureteral stents can be an alternative to percutaneous nephrostomy (PCN) in refractory ureteral stenosis. Our aim is to analyse results and complications of ureteral stents in our centre.

Methods: Retrospective review of OptiMed® expandable ureteral stents placed in our centre (1996-2022).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!