A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preparation of Fe-MOFs by microwave-assisted ball milling for reducing Cr(vi) in wastewater. | LitMetric

Preparation of Fe-MOFs by microwave-assisted ball milling for reducing Cr(vi) in wastewater.

Dalton Trans

College of Materials Science and Engineering, Hunan University, Hunan Changsha 410082, PR China.

Published: December 2017

Fe-Based metal-organic frameworks (Fe-MOFs) were prepared with trimesic acid and FeSO·7HO via a microwave-assisted ball milling approach. The structure and thermal stability of the as-prepared Fe-MOFs were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectrometry (FTIR), X-ray photoelectron spectroscopy (XPS), and thermogravimetric analysis (TGA). When used to degrade 20 mg L hexavalent chromium in aqueous solution, the Fe-MOFs were found to completely reduce a 100 mL solution within 120 min under natural light and a 400 mL solution within 90 min under Xe lamp irradiation. Under natural sunlight, 98% of the Cr(vi) was removed from a 40 mL solution after 40 min.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c7dt03776gDOI Listing

Publication Analysis

Top Keywords

microwave-assisted ball
8
ball milling
8
solution min
8
preparation fe-mofs
4
fe-mofs microwave-assisted
4
milling reducing
4
reducing crvi
4
crvi wastewater
4
wastewater fe-based
4
fe-based metal-organic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!