Purpose: This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination.

Methods: The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found.

Results: Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility (< 10 cycles per minute), and the difference between near and distance phoria (> 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity).

Conclusion: The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near phoria, and monocular accommodative facility yield good sensitivity and specificity for diagnosis of NSBVAs in a community set-up.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cxo.12628DOI Listing

Publication Analysis

Top Keywords

test battery
32
minimum test
28
binocular vision
16
receiver operating
16
operating characteristic
16
vision anomalies
12
point convergence
12
convergence penlight
12
penlight red
12
red filter
12

Similar Publications

All-solid-state fluoride-ion batteries (FIBs) have attracted extensive attention as candidates for next-generation energy storage devices; however, promising cathodes with high energy density are still lacking. In this study, CuN is investigated as a cathode material for all-solid-state fluoride-ion batteries, which offers enough anionic vacancies around the 2-fold coordinated Cu center for F intercalation, thereby enabling a multielectron-transferred fluorination process. The contribution of both cationic and anionic redox to charge compensation, in particular, the generation of molecular nitrogen species in highly charged states, has been proved by several synchrotron-radiation-based spectroscopic technologies.

View Article and Find Full Text PDF

Background Cosmetics have become an integral part of the contemporary lifestyle. Contact dermatitis (CD) is an inflammatory skin disease resulting from exposure to an external chemical present in cosmetics. A patch test is considered the criterion standard method for detecting CD.

View Article and Find Full Text PDF

Background: Reading impairments, a common consequence of stroke-induced aphasia, significantly hinder life participation, affecting both functional and leisure activities. Traditional post-stroke rehabilitation strategies often show limited generalization beyond trained materials, underscoring the need for novel interventions targeting the underlying neural mechanisms.

Method: This study investigates the feasibility and potential effectiveness of real-time functional magnetic resonance imaging (fMRI) neurofeedback (NFB) intervention for reading deficits associated with stroke and aphasia.

View Article and Find Full Text PDF

Genotoxicity evaluation of fucoidan-rich sporophyll.

Toxicol Res

January 2025

Department of Health Functional New Materials, Duksung Women's University, Seoul, 01369 Republic of Korea.

Unlabelled: The aim of this study was to investigate genotoxicity of fucoidan-rich sporophyll (FUPS) using a three-component test battery. Our sulfate analysis method showed that FUPS extract contained 14% fucoidan sulfate. The reverse mutation assay showed that the FUPS extract did not increase the number of revertant colonies in any of the five bacterial strains tested, regardless of metabolic activation by S9 mix.

View Article and Find Full Text PDF

Li-ion and Na-ion batteries are promising systems for powering electric vehicles and grid storage. Layered 3d transition metal oxides ATMO (A = Li, Na; TM = 3d transition metals; 0 < x ≤ 2) have drawn extensive attention as cathode materials due to their exceptional energy densities. However, they suffer from several technical challenges caused by crystal structure degradation associated with TM ions migration, such as poor cycling stability, inferior rate capability, significant voltage hysteresis, and serious voltage decay.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!