Objective: To present our experience of balloon-assisted maturation with drug-eluting balloon dilation in patients with recurrent failing arteriovenous fistulae.
Case Series: Three patients (all males, mean age 71 years) with a complex history of failed attempts at native fistula creation underwent surgical creation of arteriovenous fistulae. Two patients had a two-stage brachio-brachial fistula and 1 had a brachio-cephalic fistula that also required subsequent elevation. After a few weeks of preserved patency with a thrill detected clinically, all patients had a gradual deterioration of flow manifested with loss of thrill and multiple severely stenotic lesions of neo-intimal hyperplasia seen on duplex ultrasound. All 3 non-maturing native arteriovenous fistulae had 1 or more angioplasties with regular balloons that were initially successful; however, they rapidly deteriorated with a loss of thrill and a recurrence of multiple stenosis. Drug-eluting balloon dilation was used subsequently as a last resort to save these failing fistulae. All procedures were successful with the preservation of patency and adequate fistula flow (>600 mL/min) during the follow-up period (4-8 months, mean 6 months), and all patients received successful dialysis with 2-needle cannulation of their fistulae. There were no adverse events during the study period.
Conclusions: Drug-eluting balloon angioplasty was to salvage nonmaturing fistulae with durable results in complex patients where conventional treatment had previously failed. Drug-eluting balloons may provide a useful treatment option for patients prone to multiple access failures due accelerated neo-intimal hyperplasia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5301/jva.5000819 | DOI Listing |
Am Heart J
January 2025
Clinical and Experimental Interventional Cardiology, University of Saarland, Homburg, Germany.
Background And Rationale: In-stent restenosis (ISR) remains the leading cause of treatment failure following percutaneous coronary intervention (PCI) with contemporary drug-eluting stents. Especially in small caliber coronary arteries, restenosis is common following PCI and represents a treatment challenge. Drug-coated balloons (DCB) are an attractive alternative to stents for treatment of both ISR and small vessel disease.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Accident and Emergency, Etlik City Hospital, Ankara 06170, Turkey.
Arterial diseases (ADs) are a significant health problem, with high mortality and morbidity rates. Endovascular interventions, such as balloon angioplasty (BA), bare-metal stents (BMSs), drug-eluting stents (DESs) and drug-coated balloons (DCBs), have made significant progress in their treatments. However, the issue has not been fully resolved, with restenosis remaining a major concern.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Gangnam-gu, South Korea.
Background: There is a paucity of data regarding drug-coated balloon (DCB) treatment in the context of left main (LM) true bifurcation lesions.
Aims: The aim of this study was to evaluate the safety and efficacy of DCB-based treatment for unprotected LM true bifurcation lesions.
Methods: A total of 39 patients with LM true bifurcation lesion (Medina: 1,1,1/0,1,1/1,0,1) who were successfully treated with DCB alone or in combination with drug-eluting stent (DES) were retrospectively enrolled into the DCB-based group.
Circ Cardiovasc Interv
January 2025
Department of Cardiology, Odense University Hospital, Denmark (K.N.H., J.T., M.N., M.H., J.E.-G., K.T.V., A.J., H.S.H., J.F.L., L.O.J.).
Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.
Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.
J Cardiol Cases
October 2024
Department of Cardiology, Mater Dei Hospital, Msida, Malta.
Unlabelled: Pulmonary vein (PV) stenosis is a rare complication following PV isolation (PVI) for atrial fibrillation. Despite the benefit of early intervention, screening is not conducted, emphasizing the importance of maintaining a high index of suspicion. Standardized management approaches are unavailable for this serious complication.