Objective: It is intuitive to suggest that knowledge of the variation in the anatomy of the aortic root may influence the outcomes of transcatheter implantation of the aortic valve (TAVI). We have now assessed such variation.

Methods: We used 26 specimens of normal hearts and 78 CT data sets of adults with a mean age of 64±15 years to measure the dimensions of the membranous septum and to assess any influence played by rotation of the aortic root, inferring the relationship to the atrioventricular conduction axis.

Results: The aortic root was positioned centrally in the majority of both cohorts, although with significant variability. For the cadaveric hearts, 14 roots were central (54%), 4 clockwise-rotated (15%) and 8 counterclockwise-rotated (31%). In the adult CT cohort, 44 were central (56%), 21 clockwise-rotated (27%) and 13 counterclockwise-rotated (17%). A mean angle of 15.5° was measured relative to the right fibrous trigone in the adult CT cohort, with a range of -32° to 44.7°. The dimensions of the membranous septum were independent of rotation. Fibrous continuity between the membranous septum and the right fibrous trigone increased with counterclockwise to clockwise rotation, implying variation in the relationship to the atrioventricular conduction axis.

Conclusions: The central fibrous body is wider, providing greater fibrous support, in the setting of clockwise rotation of the aortic root. Individuals with this pattern may be more vulnerable to conduction damage following TAVI. Knowledge of such variation may prove invaluable for risk stratification.

Download full-text PDF

Source
http://dx.doi.org/10.1136/heartjnl-2017-312390DOI Listing

Publication Analysis

Top Keywords

aortic root
20
membranous septum
16
rotation aortic
12
knowledge variation
8
dimensions membranous
8
relationship atrioventricular
8
atrioventricular conduction
8
adult cohort
8
fibrous trigone
8
clockwise rotation
8

Similar Publications

Objective: Giant cell arteritis (GCA) may present as proximal aortic pathology requiring surgical intervention. We present our experience with surgical management of GCA in patients presenting with proximal aortic disease.

Methods: From January 1993 to May 2020, 184 adult patients were diagnosed with GCA on histopathology after undergoing cardiac surgery.

View Article and Find Full Text PDF

Background: Whether elderly patients with aortic root or ascending aortic aneurysm (ATAA) would benefit from the new surgical size threshold of 5.0 cm is unknown. This study aimed to evaluate the natural history of ATAA in elderly patients and to compare long-term outcomes of those who underwent initial surveillance versus surgery.

View Article and Find Full Text PDF

Objective: The study objective was to investigate the effect of free-edge length on valve performance in bicuspidization repair of congenitally diseased aortic valves.

Methods: In addition to a constructed unicuspid aortic valve disease model, 3 representative groups-free-edge length to aortic diameter ratio 1.2, 1.

View Article and Find Full Text PDF

Objective: A novel approach to 3-dimensional morphometry of the thoracic aorta was developed by applying centerline analysis based on least-squares plane fitting, and a preliminary study was conducted using computed tomography imaging data.

Methods: We retrospectively compared 3 groups of patients (16 controls without aortic disease, and 16 cases each with acute type B aortic dissection and congenital bicuspid aortic valve). In addition to the standard assessment indices for curvature κ and torsion τ, we conducted coordinate transformation based on the least-squares plane, divided the centerline into 3 representative features (transverse, anterior-posterior, and longitudinal displacements), and analyzed the overall and local displacement in each direction.

View Article and Find Full Text PDF

Hybrid procedure of hypoplastic left heart syndrome, comprising ductus arteriosus stenting and bilateral pulmonary artery banding, is a good surgical option for initial palliative procedure for high-risk patients for Norwood procedure. However, ductal stenting may cause retrograde aortic blood flow obstruction. Furthermore, complete removal of stent while performing the Norwood procedure make the operation more difficult.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!