Background: Conventional prosthetic feet like energy storage and return feet provide only a limited range of ankle motion compared to human ones. In order to overcome the poor rotational adaptability, prosthetic manufacturers developed different prosthetic feet with an additional rotational joint and implemented active control in different states. It was the aim of the study to investigate to what extent these commercially available microprocessor-controlled prosthetic feet support a natural posture while standing on inclines and which concept is most beneficial for lower limb amputees.
Methods: Four unilateral transtibial and four unilateral transfemoral amputees participated in the study. Each of the subjects wore five different microprocessor-controlled prosthetic feet in addition to their everyday feet. The subjects were asked to stand on slopes of different inclinations (level ground, upward slope of 10°, and downward slope of -10°). Vertical ground reaction forces, joint torques and joint angles in the sagittal plane were measured for both legs separately for the different situations and compared to a non-amputee reference group.
Results: Differences in the biomechanical parameters were observed between the different prosthetic feet and compared to the reference group for the investigated situations. They were most prominent while standing on a downward slope. For example, on the prosthetic side, the vertical ground reaction force is reduced by about 20%, and the torque about the knee acts to flex the joint for feet that are not capable of a full adaptation to the downward slope. In contrast, fully adaptable feet with an auto-adaptive dorsiflexion stop show no changes in vertical ground reaction forces and knee extending torques.
Conclusions: A prosthetic foot that provides both, an auto-adaptive dorsiflexion stop and a sufficient range of motion for fully adapting to inclinations appears to be the key element in the prosthetic fitting for standing on inclinations in lower limb amputees. In such situations, this prosthetic concept appears superior to both, conventional feet with passive structures as well as feet that solely provide a sufficient range of motion. The results also indicate that both, transfemoral and transtibial amputees benefit from such a foot.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5691831 | PMC |
http://dx.doi.org/10.1186/s12984-017-0322-2 | DOI Listing |
Disabil Rehabil
January 2025
Shirley Ryan AbilityLab, Chicago, IL, USA.
Purpose: To evaluate the psychometric properties of performance and patient-reported outcome measures (PROMs) for custom ankle-foot orthosis (AFOs) users.
Materials And Methods: Current AFO users completed two assessments one week apart; new AFO users completed an assessment before device delivery and at one- and two-months post-delivery.
Results: Seventy current and 31 new users consented and provided data.
Best Pract Res Clin Rheumatol
January 2025
Department of Arthritis Clinic and Research Center, Peking University People's Hospital, Beijing, 100044, China. Electronic address:
The past several decades have seen significant advancements in joint replacement surgery for rheumatoid arthritis (RA). Joint replacement procedures have become vital options for patients with severe joint damage and functional impairment. There has been an increased emphasis on personalized surgical strategies that tailor joint replacement decisions based on a patient's unique clinical characteristics and the extent of joint damage.
View Article and Find Full Text PDFGait Posture
January 2025
Department of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam and Amsterdam Movement Sciences, Amsterdam, the Netherlands; Department of Research and Development, Military Rehabilitation Centre Aardenburg, Doorn, the Netherlands.
Background: The alignment of a bone-anchored prosthesis has consequences for the external moments around the residual joints and implant, and these external moments can lead to serious negative long-term effects. A clear understanding of the relationship between transtibial prosthetic alignment and external joint and implant moment for bone-anchored prosthetic users is still lacking.
Research Question: What is the effect of systematic frontal plane prosthetic alignment changes on lower limb external joint moments in people with a transtibial bone-anchored prosthesis?
Methods: Participants underwent gait analysis on an instrumented dual belt treadmill.
Foot Ankle Surg
January 2025
Foot and Ankle Division, Department of Orthopaedic Surgery, NYU Langone Health, New York City, NY 10002, USA. Electronic address:
Background: The purpose of this systematic review was to evaluate the impact of mental health disorders (MHDs) on the clinical and functional outcomes following total ankle arthroplasty (TAA) for the treatment of end-stage ankle arthritis.
Methods: A systematic review of the EMBASE, MEDLINE, and Cochrane Library databases was conducted in April 2024 following PRISMA guidelines. Data collected included patient demographics, clinical outcomes, complications, and failures.
Sci Rep
January 2025
Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA.
Over 50% of individuals with lower limb loss report a fear of falling and avoiding daily activities partly due to a lack of plantar sensation. Providing direct somatosensory feedback via neural stimulation holds promise for addressing this issue. In this study, three individuals with lower limb loss received a sensory neuroprosthesis (SNP) that provided plantar somatosensory feedback corresponding to prosthesis-floor interactions perceived as arising from the missing foot generated by electrically activating the peripheral nerves in the residuum.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!