Azathioprine is the main thiopurine drug used in the treatment of immune-based inflammations of gastrointestinal tract. For the purpose of therapy control and optimization, effective and reliable analytical methods for a rapid drug monitoring in biological fluids are essential. Here, we developed a separation method based on the capillary electrophoresis (CE) hyphenated with tandem mass spectrometry (MS/MS) for the simultaneous determination of azathioprine and its selected metabolites (6-thioguanine, 6-mercaptopurine, and 6-methylmercaptopurine) as well as other co-medicated drugs (mesalazine, prednisone, and allopurinol). The optimized CE-MS/MS conditions provided a very efficient and stable system for the separation and sensitive detection of these drugs in human urine matrices. The developed method was successfully applied for the assay of the targeted drugs and their selected metabolites in urine samples collected from patients suffering from inflammatory bowel disease (IBD) and receiving azathioprine therapy. The developed CE-MS/MS method, due to its reliability, short analysis time, production of complex clinical profiles, and favorable performance parameters, evaluated according to FDA guidelines for bioanalytical method validation, is proposed for routine clinical laboratories to optimize thiopurine therapy, estimate enzymatic activity, and control patient compliance with medication and co-medication.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6150202 | PMC |
http://dx.doi.org/10.3390/molecules22111973 | DOI Listing |
J Microsc
January 2025
Faculty of Medicine Carl Gustav Carus, Experimental Center, Technische Universität Dresden, Dresden, Germany.
Ribosomes, discovered in 1955 by George Palade, were initially described as small cytoplasmic particles preferentially associated with the endoplasmic reticulum (ER). Over the years, extensive research has focused on both the structure and function of ribosomes. However, a fundamental question - how many ribosomes are present within whole cells - has remained largely unaddressed.
View Article and Find Full Text PDFAquat Toxicol
January 2025
Laboratory of Biomarkers of Aquatic Contamination and Immunochemistry-LABCAI, Federal University of Santa Catarina - UFSC, Florianópolis, SC 88037-000, Brazil. Electronic address:
Personal care products (PCPs), such as sunscreens, are usually found in various aquatic ecosystems at low concentrations (ng l to µg l). However, there is limited information regarding their effects on marine bivalves. Therefore, the aim of this study was to evaluate the sublethal effects of environmental concentrations (1 and 100 µg l) of benzophenone-3 (BP-3) in Crassostrea gigas oysters after 1 and 7 days of exposure.
View Article and Find Full Text PDFJ Pharm Biomed Anal
January 2025
State Key Laboratory of Neurology and Oncology Drug Development, Nanjing, China; Simcere Zaiming Pharmaceutical Co, Ltd., Nanjing, China. Electronic address:
Capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) is widely used in the biopharmaceutical industry for monitoring purity and analyzing impurities. The accuracy of the method may be compromised by artificial species resulting from sample preparation or electrophoresis separation due to suboptimal conditions. During non-reduced CE-SDS analysis of a multispecific antibody (msAb), named as multispecific antibody C (msAb-C), a cluster of unexpected peaks was observed after the main peak.
View Article and Find Full Text PDFBackground: Hemoglobin G-Siriraj is a rare hemoglobin variant caused by a β-globin gene mutation (HBB: c.22G>A). The focus of this paper is aimed mainly at the chromatographic and electrophoretic properties of hemoglobin G-Siriraj for a presumptive identification.
View Article and Find Full Text PDFBackground: Glycosylated hemoglobin (HbA1c) is a stable compound in human blood that covalently binds the N-terminal valine residue of the β-chain in hemoglobin A to the free aldehyde group of glucose. It can reflect the average blood glucose level of patients in the past 2 - 3 months. Therefore, the accuracy of HbA1c detection results is of great significance for the diagnosis and differential diagnosis of diabetes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!