Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To demonstrate how the concept of hemidivisional corneal topographic astigmatism (hemiCorT) enables the planning of hemidivisional corneal treatments to reduce irregularity and overall astigmatism.
Methods: Whole-of-cornea corneal topographic astigmatism (CorT) is calculated from topography data derived from a corneal topographer or tomographer. The cornea is conceptually divided into 2 hemidivisions along the flat meridian of the CorT. For each hemidivision, hemiCorTs are calculated. The regularization treatment for each hemidivision is the treatment required to target the whole-of-cornea CorT, which is a symmetrical orthogonal corneal astigmatism. The regularization is then combined with astigmatism reduction treatment, which could be a conventional refractive treatment or a vector-planned treatment. For each hemidivision, the combined astigmatic effect of the regularization treatment and reduction treatment can be determined through double-angle vector summation. The 2 hemidivisional treatments together regularize and reduce corneal astigmatism.
Results: A theoretical pair of hemidivisional treatments is derived from an actual example of a cornea displaying idiopathic asymmetric nonorthogonal astigmatism.
Conclusions: HemiCorTs allow for the design of hemidivisional corneal treatments of asymmetric nonorthogonal astigmatism. Such treatments should be suitable in the routine treatment of commonly occurring irregular astigmatism, while also allowing the spherical refractive error to be treated concurrently.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICO.0000000000001448 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!