A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Comparison of Anterograde Versus Retrograde Approaches for Neonatal Balloon Aortic Valvuloplasty. | LitMetric

In neonates requiring balloon aortic valvuloplasty, both anterograde and retrograde approaches are feasible. A recent comparison of these two approaches is lacking. A retrospective cohort study of neonates at a single center undergoing BAV from 9/00 to 7/14 was performed. Records were reviewed including pre- and post-intervention echocardiograms and catheterization data. Comparisons of acute efficacy and procedural safety were made based on type of approach utilized. Forty-two neonates underwent BAV. Eleven cases utilized exclusively an anterograde approach, while 31 included a retrograde approach (including 4 with both approaches used). There were no significant differences between groups in baseline demographic and clinical characteristics. Additionally, by both pre-intervention echocardiogram and catheterization, there were no differences based on approach in aortic valve gradient, degree of aortic insufficiency (AI), or degree of mitral regurgitation (MR). Both approaches were equally efficacious in gradient reduction (45 ± 17 vs. 44 ± 21 mmHg, p = 0.97), and there was no difference in post-intervention AI as assessed by both catheterization and echocardiogram (52% vs. 64% none or trivial, p = 0.74). Additionally, there was no difference in the proportion of patients with an increased severity of MR after BAV (15% vs. 22%, p = 0.52). The retrograde approach required a larger arterial catheter and was associated with a higher rate of arterial thrombosis (61% vs. 18%, p = 0.014). Both anterograde and retrograde approaches to neonatal BAV appear to be equally efficacious in the short term. The anterograde approach avoids the need for a larger arterial catheter and may reduce the risk of arterial thrombosis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00246-017-1772-9DOI Listing

Publication Analysis

Top Keywords

retrograde approaches
12
approaches neonatal
8
balloon aortic
8
aortic valvuloplasty
8
anterograde retrograde
8
anterograde approach
8
retrograde approach
8
equally efficacious
8
larger arterial
8
arterial catheter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!