A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preconcentration and partial separation of nitroaromatic vapors using a methyltrimethoxysilane-based sol-gel. | LitMetric

Preconcentration and partial separation of nitroaromatic vapors using a methyltrimethoxysilane-based sol-gel.

J Chromatogr A

Chemistry Division, U.S. Naval Research Laboratory, 4555 Overlook Ave SW, Washington, DC 20375, United States. Electronic address:

Published: December 2017

Typical trace vapor analysis involves sorbent trapping, followed by desorption and chromatographic separation. This communication describes a method for streamlining this process by combining sorbent sampling/preconcentration with partial separation achieved through temperature-programmed thermal desorption. A novel sorbent trap was formulated in which tubular glass liners for a programmable-temperature gas chromatograph inlet were coated with a sol-gel based polymer stationary phase synthesized from methyltrimethoxysilane precursor and installed into the inlet, which was directly connected to a mass-selective detector by a fused silica capillary transfer line. This method is shown to achieve partial separation of two nitroaromatic vapors in a total 3-5min analysis time, which represents a tenfold improvement in speed in terms of the overall cycle time compared to an analogous conventional vapor analysis method. Both analytes proved to have a high dynamic range and loading capacity, with nitrobenzene achieving both high and low sampling extremes (0.32ng-4μg sampling concentration) with only a slight compromise in peak broadening. The multivariate curve resolution by alternating least squares algorithm (MCR-ALS) was shown to successfully resolve the overlapped elution profiles of the two nitroaromatic test vapors examined in this study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2017.11.006DOI Listing

Publication Analysis

Top Keywords

partial separation
12
separation nitroaromatic
8
nitroaromatic vapors
8
vapor analysis
8
preconcentration partial
4
separation
4
vapors methyltrimethoxysilane-based
4
methyltrimethoxysilane-based sol-gel
4
sol-gel typical
4
typical trace
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!