Reliable recognition of pain is difficult in ferrets as many currently available parameters are non-specific, inconsistent and/or impractical. Grimace scales have successfully been applied to assess pain in different animal species and might also be applicable to ferrets. To compose a Ferret Grimace Scale (FGS), we studied the facial musculature of ferrets and compared lateral photographs of 19 ferret faces at six time points before and after intraperitoneal telemetry probe implantation. We identified the Action Units (AUs) orbital tightening, nose bulging, cheek bulging, ear changes and whisker retraction as potential indicators of pain in ferrets. To evaluate whether these AUs could reliably be used to identify photographs taken before and after surgery, the photographs were scored 0, 1 or 2 (not, moderately or obviously present) by 11 observers that were blinded to the treatment and timing of the photographs. All AU-scores assigned to the photographs taken five hours after surgery were significantly higher compared to their time-matched baseline scores. Further analysis using the weights that were obtained using a Linear Discriminant Analysis revealed that scoring orbital tightening alone was sufficient to make this distinction with high sensitivity, specificity and accuracy. Including weighted scores for nose bulging, cheek bulging and ear change did not change this. As these AUs had more missing values than orbital tightening, their descriptions should be re-evaluated. Including whisker retraction, which had a negative weight, resulted in lower accuracy and should therefore in its current form be left out of the FGS. Overall, the results of this study suggest that the FGS and the AU orbital tightening in particular could be useful in a multifactorial pain assessment protocol for ferrets. However, before applying the FGS in practice, it should be further validated by incorporating more time points before and after applying (different) painful stimuli, and different levels of analgesia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5683639PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0187986PLOS

Publication Analysis

Top Keywords

orbital tightening
16
grimace scale
8
telemetry probe
8
time points
8
nose bulging
8
bulging cheek
8
cheek bulging
8
bulging ear
8
whisker retraction
8
ferrets
6

Similar Publications

Effectiveness of comprehensive approach in rejuvenating the aging lower periorbita.

Int Ophthalmol

December 2024

Department of Ophthalmology, Ankara Training and Research Hospital, University of Health Sciences, Ankara, Turkey.

Purpose: To investigate the efficacy of a comprehensive surgical approach for rejuvenation of the aging lower periorbita.

Methods: Between February 2018 and January 2023, 80 eyes of 40 patients with lower lid dermatochalasis (LLD), lower lid laxity (LLL) or orbicularis laxity of the lower lid (OL) admitted to the oculoplastic surgery department of our clinic were included in the study. 18 eyes had LLD, 14 eyes had LLL, 18 eyes had LLD and LLL, and 30 eyes had LLD, LLL and OL.

View Article and Find Full Text PDF

Effects of training on Feline Grimace Scale scoring for acute pain assessment in cats.

J Feline Med Surg

October 2024

Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, QC, Canada.

Article Synopsis
  • The study aimed to assess how training impacts the consistency and agreement of small animal veterinarians when using the Feline Grimace Scale (FGS) to score cat pain.
  • Seven veterinarians evaluated 50 images of cats before and after receiving training, with their scores compared to an expert rater to determine inter-rater reliability.
  • Results showed improved reliability after training, with scores classified as moderate to good, indicating that the training effectively enhanced the veterinarians' abilities to assess cat pain accurately.
View Article and Find Full Text PDF

Grimace scales have been used to assess pain in various animal species. This study aimed to develop the calf grimace scale (CGS), evaluate its responsiveness and the effect of external factors (change of environment and dam separation, and restraint) on CGS. Sixty-nine Angus calves, 6-8 weeks old, were randomly allocated into castrated (n = 34) and sham castrated (n = 35) groups.

View Article and Find Full Text PDF

Photorefractive keratectomy (PRK) is a type of eye surgery that involves removal of the corneal epithelium and its associated nerves, which causes intense acute pain in most people. We used a rat model of corneal epithelium removal (corneal abrasion) to examine underlying cellular and molecular mechanisms. In this study, we used immunohistochemistry of trigeminal ganglion (TG) to assess neuronal content of CGRP and ATF3, as well as orbital tightening (OT) to assess spontaneous pain behaviors.

View Article and Find Full Text PDF

Quantitative orbital tightening for pain assessment using machine learning with DeepLabCut.

Neurobiol Pain

September 2024

Department of Anesthesiology and Perioperative Medicine, School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, United States.

Pain assessment in animal models is essential for understanding mechanisms underlying pathological pain and developing effective pain medicine. The grimace scale (GS), facial expression features in pain such as orbital tightening (OT), is a valuable measure for assessing pain in animal models. However, the classical grimace scale for pain assessment is labor-intensive, subject to subjectivity and inconsistency, and is not a quantitative measure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!