Intracortical microelectrodes have shown great success in enabling locked-in patients to interact with computers, robotic limbs, and their own electrically driven limbs. The recent advances have inspired world-wide enthusiasm resulting in billions of dollars invested in federal and industrial sponsorships to understanding the brain for rehabilitative applications. Additionally, private philanthropists have also demonstrated excitement in the field by investing in the use of brain interfacing technologies as a means to human augmentation. While the promise of incredible technologies is real, caution must be taken as implications regarding optimal performance and unforeseen side effects following device implantation into the brain are not fully characterized. The current study is aimed to quantify any motor deficit caused by microelectrode implantation in the motor cortex of healthy rats compared to non-implanted controls. Following electrode insertion, rats were tested on an open-field grid test to study gross motor function and a ladder test to study fine motor function. It was discovered that rats with chronically indwelling intracortical microelectrodes exhibited up to an incredible 527% increase in time to complete the fine motor task. This initial study defines the need for further and more robust behavioral testing of potential unintentional harm caused by microelectrode implantation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5681545 | PMC |
http://dx.doi.org/10.1038/s41598-017-15623-y | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Department of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125.
Cognition relies on transforming sensory inputs into a generalizable understanding of the world. Mirror neurons have been proposed to underlie this process, mapping visual representations of others' actions and sensations onto neurons that mediate our own, providing a conduit for understanding. However, this theory has limitations.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
January 2025
East China Normal University, Dept. of Chemistry, Dongchuan Road 500, 200062, Shanghai, CHINA.
Monitoring dynamic neurochemical signals in the brain of free-moving animals remains great challenging in biocompatibility and direct implantation capability of current electrodes. Here we created a self-supporting polymer-based flexible microelectrode (rGPF) with sufficient bending stiffness for direct brain implantation without extra devices, but demonstrating low Young's modulus with remarkable biocompatibility and minimal position shifts. Meanwhile, screening by density functional theory (DFT) calculation, we designed and synthesized specific ligands targeting Mg2+ and Ca2+, and constructed Mg-E and Ca-E sensors with high selectivity, good reversibility, and fast response time, successfully monitoring Mg2+ and Ca2+ in vivo up to 90 days.
View Article and Find Full Text PDFBiomaterials
January 2025
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States; Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States. Electronic address:
Intracortical microelectrodes (IMEs) are essential for neural signal acquisition in neuroscience and brain-machine interface (BMI) systems, aiding patients with neurological disorders, paralysis, and amputations. However, IMEs often fail to maintain robust signal quality over time, partly due to neuroinflammation caused by vascular damage during insertion. Platelet-inspired nanoparticles (PIN), which possess injury-targeting functions, mimic the adhesion and aggregation of active platelets through conjugated collagen-binding peptides (CBP), von Willebrand Factor-binding peptides (VBP), and fibrinogen-mimetic peptides (FMP).
View Article and Find Full Text PDFWorld Neurosurg
December 2024
Department of Neurosurgery, Institute of Psychiatry and Neurology, Warsaw, Poland, Sobieskiego 9 Street 02-957, Warsaw, Poland.
Background: Hemorrhage is a dangerous complication of deep brain stimulation (DBS) surgery, but a comprehensive explanation of the associated risk factors remains inconclusive, particularly application of microelectrode recording (MER) compared to macrostimulation (non-MER) based DBS procedures. We conducted a comparative analysis of MER and macrostimulation techniques, evaluating the impact of brain penetrations by microelectrode guiding cannulas on the occurrence of intracranial hemorrhagic events.
Methods: This retrospective study included all DBS procedures (MER-based and non-MER based) performed at a single medical center from November 2008 to June 2023.
ACS Sens
December 2024
Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China.
Three-dimensional (3D) cardiomyocyte spheroids are essential models to replicate cardiac structural and functional features in vitro. However, conventional planar and rigid microelectrode arrays (MEAs) suffer from low-quality electrophysiological recording of 3D cultures, due to limited contact areas and weak coupling between cells and MEA chips. Herein, we developed a PEDOT: PSS-modified organic flexible and implantable MEA (OFI-MEA) coupled with a self-developed integrated biosensing platform to achieve high-throughput, long-term, and stable bidirectional internal electrophysiology in 3D cardiomyocyte spheroids.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!