Hall sensors batch-fabricated on all-CVD h-BN/graphene/h-BN heterostructures.

Sci Rep

Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-41296, Göteborg, Sweden.

Published: November 2017

The two-dimensional (2D) material graphene is highly promising for Hall sensors due to its potential of having high charge carrier mobility and low carrier concentration at room temperature. Here, we report the scalable batch-fabrication of magnetic Hall sensors on graphene encapsulated in hexagonal boron nitride (h-BN) using commercially available large area CVD grown materials. The all-CVD grown h-BN/graphene/h-BN van der Waals heterostructures were prepared by layer transfer technique and Hall sensors were batch-fabricated with 1D edge metal contacts. The current-related Hall sensitivities up to 97 V/AT are measured at room temperature. The Hall sensors showed robust performance over the wafer scale with stable characteristics over six months in ambient environment. This work opens avenues for further development of growth and fabrication technologies of all-CVD 2D material heterostructures and allows further improvements in Hall sensor performance for practical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5680335PMC
http://dx.doi.org/10.1038/s41598-017-12277-8DOI Listing

Publication Analysis

Top Keywords

hall sensors
20
sensors batch-fabricated
8
room temperature
8
hall
7
batch-fabricated all-cvd
4
all-cvd h-bn/graphene/h-bn
4
h-bn/graphene/h-bn heterostructures
4
heterostructures two-dimensional
4
two-dimensional material
4
material graphene
4

Similar Publications

The frequency diverse array (FDA) is an architecture capable of beamforming in both range and angle, improving upon the traditional phased array (PA) which can only achieve beamforming in angle. The FDA employing directional modulation (DM) for secure directional communications (SDC) can reduce bit error rates (BERs) in both range and angle, again improving upon the traditional PA which can only reduce BER in angle. In this paper, we document the challenges involved in the design and implementation of a two-element linear FDA employing fast-time binary phase-shift keying (BPSK) modulations.

View Article and Find Full Text PDF

Understanding renal pelvis pressure (P) during ureteroscopy (URS) has become increasingly important. High irrigation rates, desirable to maintain visualization and limit thermal dose, can increase P. Use of a multi-channel ureteroscope (m-ureteroscope) with a dedicated drainage channel is one strategy that may facilitate simultaneous low P and high flowrate.

View Article and Find Full Text PDF

Review of advances in glycan analysis on exosomes, cancer cells, and circulating cancer-derived glycoproteins with an emphasis on electrochemistry.

Anal Chim Acta

January 2025

Department of Biomedical Engineering, Korea University, Seoul, 02841, South Korea; Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841, South Korea. Electronic address:

Glycosylation, the intricate process of adding carbohydrate motifs to proteins, lipids, and exosomes on the cell surface, is crucial for both physiological and pathological mechanisms. Alterations in glycans significantly affect cancer cell metastasis by mediating cell-cell and cell-matrix interactions. The subtle changes in glycosylation during malignant transformations highlight the importance of analyzing cell and exosome surface glycosylation for prognostic and early treatment strategies in cancer.

View Article and Find Full Text PDF

Current technologies could potentially solve many of the urban problems in today's cities. Many cities already possess cameras, drones, thermometers, pollution air gauges, and other sensors. However, most of these have been designated for use in individual domains within City Hall, creating a maze of individual data domains that cannot connect to each other.

View Article and Find Full Text PDF

Cardiac implantable electronic devices and their integrated thoracic impedance sensors have been used to detect sleep apnea for over a decade now. Despite their usage in daily clinical practice, there are only limited data on their diagnostic accuracy. AIRLESS and UPGRADE were prospective investigator-driven trials meant to validate the AP scan (Boston Scientific, Marlborough, MA, USA) in heart failure cohorts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!