Quantitative PET/MRI is dependent on reliable and reproducible MR-based attenuation correction (MR-AC). In this study, we evaluated the quality of current vendor-provided thoracic MR-AC maps and further investigated the reproducibility of their impact on F-FDG PET quantification in patients with non-small cell lung cancer. Eleven patients with inoperable non-small cell lung cancer underwent 2-5 thoracic PET/MRI scan-rescan examinations within 22 d. F-FDG PET data were acquired along with 2 Dixon MR-AC maps for each examination. Two PET images (PET and PET) were reconstructed using identical PET emission data but with MR-AC from these intrasubject repeated attenuation maps. In total, 90 MR-AC maps were evaluated visually for quality and the occurrence of categorized artifacts by 2 PET/MRI-experienced physicians. Each tumor was outlined by a volume of interest (40% isocontour of maximum) on PET, which was then projected onto the corresponding PET SUV and SUV were assessed from the PET images. Within-examination coefficients of variation and Bland-Altman analyses were conducted for the assessment of SUV variations between PET and PET Image artifacts were observed in 86% of the MR-AC maps, and 30% of the MR-AC maps were subjectively expected to affect the tumor SUV. SUV and SUV resulted in coefficients of variation of 5.6% and 6.6%, respectively, and scan-rescan SUV variations were within ±20% in 95% of the cases. Substantial SUV variations were seen mainly for scan-rescan examinations affected by respiratory motion. Artifacts occur frequently in standard thoracic MR-AC maps, affecting the reproducibility of PET/MRI. These, in combination with other well-known sources of error associated with PET/MRI examinations, lead to inconsistent SUV measurements in serial studies, which may affect the reliability of therapy response assessment. A thorough visual inspection of the thoracic MR-AC map and Dixon images from which it is derived remains crucial for the detection of MR-AC artifacts that may influence the reliability of SUV.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.117.198853DOI Listing

Publication Analysis

Top Keywords

mr-ac maps
24
pet
12
lung cancer
12
thoracic mr-ac
12
suv suv
12
suv variations
12
mr-ac
10
suv
10
mr-based attenuation
8
maps
8

Similar Publications

Purpose: Conventional magnetic resonance imaging (MRI) can for glioma assessment be supplemented by positron emission tomography (PET) imaging with radiolabeled amino acids such as O-(2-[F]fluoroethyl)-L-tyrosine ([F]FET), which provides additional information on metabolic properties. In neuro-oncology, patients often undergo brain and skull altering treatment, which is known to challenge MRI-based attenuation correction (MR-AC) methods and thereby impact the simplified semi-quantitative measures such as tumor-to-brain ratio (TBR) used in clinical routine. The aim of the present study was to examine the applicability of our deep learning method, DeepDixon, for MR-AC in [F]FET PET/MRI scans of a post-surgery glioma cohort with metal implants.

View Article and Find Full Text PDF

Background: Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system.

View Article and Find Full Text PDF

Deep learning for Dixon MRI-based attenuation correction in PET/MRI of head and neck cancer patients.

EJNMMI Phys

March 2022

Department of Clinical Physiology, Nuclear Medicine and PET & Cluster for Molecular Imaging, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark.

Background: Quantitative whole-body PET/MRI relies on accurate patient-specific MRI-based attenuation correction (AC) of PET, which is a non-trivial challenge, especially for the anatomically complex head and neck region. We used a deep learning model developed for dose planning in radiation oncology to derive MRI-based attenuation maps of head and neck cancer patients and evaluated its performance on PET AC.

Methods: Eleven head and neck cancer patients, referred for radiotherapy, underwent CT followed by PET/MRI with acquisition of Dixon MRI.

View Article and Find Full Text PDF

Deep learning for whole-body medical image generation.

Eur J Nucl Med Mol Imaging

November 2021

Joint Department of Medical Imaging, Princess Margaret Cancer Centre, Mount Sinai Hospital and Women's College Hospital, University of Toronto, University Health Network, 610 University Ave, Toronto, Ontario, M5G 2M9, Canada.

Background: Artificial intelligence (AI) algorithms based on deep convolutional networks have demonstrated remarkable success for image transformation tasks. State-of-the-art results have been achieved by generative adversarial networks (GANs) and training approaches which do not require paired data. Recently, these techniques have been applied in the medical field for cross-domain image translation.

View Article and Find Full Text PDF

Introduction: Robust and reliable attenuation correction (AC) is a prerequisite for accurate quantification of activity concentration. In combined PET/MRI, AC is challenged by the lack of bone signal in the MRI from which the AC maps has to be derived. Deep learning-based image-to-image translation networks present itself as an optimal solution for MRI-derived AC (MR-AC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!