Peritoneal dialysis (PD) is a well-established form of renal replacement therapy and the practice of leaving catheters post-transplantation widely accepted. We present a rare complication: a child presenting with anal protrusion of the PD catheter.The patient is an 11-year-old boy with a background of renal dysplasia and congenital cutis laxa. Twenty-three weeks after dialysis was commenced, the patient underwent a renal transplant. Thirteen weeks post-transplant, the patient felt an unusual sensation after defecation. The curled end of the catheter was seen protruding from the anus. He was admitted, and investigations showed stable graft function, with abdominal X ray showing no free air.Intraoperative findings showed a small perforation of the sigmoid colon sealed off by adherence of several small intestinal loops. This was repaired laparoscopically after removal of the distal part of the catheter rectum. No peritoneal contamination was seen. He was treated with 5 days of intravenous antibiotics and gradual introduction of enteral feeds. His graft function remained stable throughout.Timing of catheter removal varies, from the time of transplantation to over 3 months post-transplantation. Bowel perforation due to PD catheter insertion is rare and tends to occur at the time of insertion. Anal protrusion of a PD catheter in childhood is extremely rare and unrecorded in a pediatric patient with a connective tissue disorder. Our case highlights that serious complications can occur in the period between transplantation and elective PD catheter removal and that, in the immunocompromised patient, signs can be subtle.

Download full-text PDF

Source
http://dx.doi.org/10.3747/pdi.2016.00226DOI Listing

Publication Analysis

Top Keywords

catheter removal
12
peritoneal dialysis
8
bowel perforation
8
anal protrusion
8
graft function
8
catheter
7
patient
5
dialysis catheter
4
removal
4
removal post-transplant
4

Similar Publications

Totally implantable central venous catheters (CVCs) are widely used in the management of patients with malignant diseases. Conventionally, port implantations were carried out by general surgeons and vascular radiologists. In recent years, the medical staff of the Medical Oncology department at the Central University Hospital of Asturias (HUCA) has developed a simplified methodology for the routine implantation of these devices.

View Article and Find Full Text PDF

Background: External jugular vein (EJV) is used to insert tunneled dialysis catheter (TDC) in patients with no AVF and exhausted right internal jugular veins (IJV). There is scarce data on TDC insertion in EJV by nephrologists with fluoroscopy guidance.

Materials And Methods: This was a prospective observational study that included hemodialysis patients with exhausted right IJV access who underwent EJV TDC insertion, and excluded occluded ipsilateral brachiocephalic vein or superior vena cava, EJV < 5 mm diameter, or patients with existing EJV TDC.

View Article and Find Full Text PDF

Background: Early literature on the Woven EndoBridge (WEB) device reported 80-90% adequate aneurysm occlusion but low complete occlusion (40-55%). It is uncertain whether residual or recurrent aneurysms require re-treatment to prevent future rupture.

Objective: To systematically review the literature to meta-analyze occlusion and complication rates after re-treatment of these aneurysms.

View Article and Find Full Text PDF

Challenges in extracting a defective ventricular lead after CRT-D: a case report.

Front Cardiovasc Med

January 2025

Department of Cardiology, University of Health Sciences, Erzurum Bolge Training and Research Hospital, Erzurum, Turkey.

Background: Our aim in this case was to remove the defective ventricular lead and the ruptured coronary sinus lead.

Methods: Entering through the right femoral vein and removing the coronary sinus lead with a pigtail catheter.

Results: In our attempt to extract the coronary sinus lead, it fractured.

View Article and Find Full Text PDF

Background: In general, it is relatively easy to remove peripherally inserted central venous catheter (PICC) by gentle traction without any complications. However, the removal of PICC can be challenging occasionally. If the standard interventions fail to remove the catheter, there are no clear recommendations about what to do.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!