Background: Cardiac output (CO) is an important haemodynamic parameter to monitor in patients during surgery. However, the majority of the techniques for measuring CO have a limited application in veterinary practice due to their invasive approach and associated complexity and risks. Transoesophageal echocardiography (TEE) is a technique used to monitor cardiac function in human patients during surgical procedures and allows CO to be measured non-invasively. This prospective clinical study aimed to compare the transoesophageal echocardiography using a transgastric view of the left ventricular outflow tract (LVOT) and the thermodilution (TD) technique for the assessment of CO during mean arterial pressure of 65-80 mmHg (normotension) and <65 mmHg (hypotension) in dogs undergoing elective surgery. Eight dogs were pre-medicated with acepromazine (0.05 mg/kg, IM), tramadol (4 mg/kg, IM) and atropine (0.03 mg/kg, IM), followed by anaesthetic induction with propofol (3-5 mg/kg IV) and maintenance with isoflurane associated with a continuous infusion rate of fentanyl (bolus of 3 μg/kg followed by 0.3 μg/kg/min). The CO was measured by TEE (CO) and TD (CO) at the end of expiration during normotension and hypotension (induced by isoflurane).

Results: There was a strong positive correlation between CO and CO ​​(r = 0.925; P < 0.0001). The bias between CO and CO was 0.14 ± 0.29 L/min (limits of agreement, -0.44 to 0.72 L/min). The percentage error of CO measured by the two methods was 12.32%. In addition, a strong positive correlation was found between CO and CO during normotension (r = 0.995; P < 0.0001) and hypotension (r = 0.78; P = 0.0223).

Conclusions: The results of this study indicated that the transgastric view of the LVOT by TEE was a minimally invasive alternative to clinically monitoring CO in dogs during anaesthesia. However, during hypotension, the CO obtained by TEE was less reliable, although still acceptable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5679384PMC
http://dx.doi.org/10.1186/s12917-017-1227-9DOI Listing

Publication Analysis

Top Keywords

transoesophageal echocardiography
12
cardiac output
8
thermodilution technique
8
clinical monitoring
4
monitoring cardiac
4
output assessed
4
assessed transoesophageal
4
echocardiography anaesthetised
4
anaesthetised dogs
4
dogs comparison
4

Similar Publications

Evaluating cardiac performance in beagle dogs: Transesophageal echocardiography and myocardial work assessment.

Heliyon

January 2025

Department of Ultrasound Medicine, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, 210008, People's Republic of China.

Objectives: This study aimed to establish standard transesophageal echocardiographic (TEE) measurements of left ventricular (LV) morphology, function, and myocardial work parameters in healthy Beagle dogs using pressure-strain loops (PSL). Additionally, it sought to standardize optimal TEE imaging techniques and explore the potiential application of myocardial work analyis in veterinary medicine.

Methods: Thirty-seven healthy male Beagle dogs were anesthetized, intubated, and mechanically ventilated for TEE examinations.

View Article and Find Full Text PDF

Transcatheter aortic valve repair (TAVR) presents a minimally invasive alternative to traditional surgical valve replacement, albeit not without its own set of complications. A rare complication is the infolding of the self-expanding valve, which can precipitate cardiac arrest. The estimated incidence rate of this complication stands at 1.

View Article and Find Full Text PDF

To assess the efficacy and safety of "one-stop" procedures combining radiofrequency catheter ablation and left atrial appendage closure by guidance of intracardiac echocardiography(ICE) in elderly patients with atrial fibrillation. A retrospective cohort study was conducted on patients who underwent ICE-guided "one-stop" procedures at the Department of Cardiology, General Hospital of Northern Theater Command between December 2020 and January 2023. Patients were divided into elderly group (age≥60 years old) and non-elderly group (age 18-59 years old).

View Article and Find Full Text PDF

Background: Historically, percutaneous transcatheter left atrial appendage closure (LAAC) has been performed under general anesthesia (GA) with transesophageal echocardiographic images obtained by a noninvasive cardiologist and usually requires an overnight hospital stay. Alternatively, we present our single-center experience performing LAACs under deep sedation (DS), employing an echocardiographic technician instead of a noninvasive cardiologist, and expediting same-day discharge. Mid- to long-term outcomes were also evaluated with follow-up imaging at a 45-day visit.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!