Purpose: The purpose of this study was to implement Virtual Phantom Magnetic Resonance Imaging (ViP MRI), a technique that allows for generating reference signals in MR images using radiofrequency (RF) signals, on a clinical MR system and to test newly designed virtual phantoms.
Methods: MRI experiments were conducted on a 1.5 T MRI scanner. Electromagnetic modelling of the ViP system was done using the principle of reciprocity. The ViP RF signals were generated using a compact waveform generator (dimensions of 26 cm × 18 cm × 16 cm), connected to a homebuilt 25 mm-diameter RF coil. The ViP RF signals were transmitted to the MRI scanner bore, simultaneously with the acquisition of the signal from the object of interest. Different types of MRI data acquisition (2D and 3D gradient-echo) as well as different phantoms, including the Shepp-Logan phantom, were tested. Furthermore, a uniquely designed virtual phantom - in the shape of a grid - was generated; this newly proposed phantom allows for the investigations of the vendor distortion correction field.
Results: High quality MR images of virtual phantoms were obtained. An excellent agreement was found between the experimental data and the inverse cube law, which was the expected functional dependence obtained from the electromagnetic modelling of the ViP system. Short-term time stability measurements yielded a coefficient of variation in the signal intensity over time equal to 0.23% and 0.13% for virtual and physical phantom, respectively. MR images of the virtual grid-shaped phantom were reconstructed with the vendor distortion correction; this allowed for a direct visualization of the vendor distortion correction field. Furthermore, as expected from the electromagnetic modelling of the ViP system, a very compact coil (diameter ~ cm) and very small currents (intensity ~ mA) were sufficient to generate a signal comparable to that of physical phantoms in MRI experiments.
Conclusions: The ViP MRI technique was successfully implemented on a clinical MR system. One of the major advantages of ViP MRI over previous approaches is that the generation and transmission of RF signals can be achieved with a self-contained apparatus. As such, the ViP MRI technique is transposable to different platforms (preclinical and clinical) of different vendors. It is also shown here that ViP MRI could be used to generate signals whose characteristics cannot be reproduced by physical objects. This could be exploited to assess MRI system properties, such as the vendor distortion correction field.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mp.12658 | DOI Listing |
Neuroradiology
January 2025
Medical School of Chinese PLA, No.28 Fuxing Road, Haidian District, Beijing, 100853, China.
Purpose: In primary central nervous system lymphoma (PCNSL), B-cell lymphoma-6 (BCL-6) is an unfavorable prognostic biomarker. We aim to non-invasively detect BCL-6 overexpression in PCNSL patients using multiparametric MRI and machine learning techniques.
Methods: 65 patients (101 lesions) with primary central nervous system lymphoma (PCNSL) diagnosed from January 2013 to July 2023, and all patients were randomly divided into a training set and a validation set according to a ratio of 8 to 2.
Eur J Nucl Med Mol Imaging
January 2025
Department of Nuclear Medicine and PET, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Purpose: To investigate the efficacy of [Ga]Ga-FAPI-04 PET/CT for assessing viable tumours (VTs) after local regional treatment (LRT) in hepatocellular carcinoma (HCC) patients. The related imaging features of HCC after LRT are preliminarily discussed.
Methods: A cohort of 37 LRT patients with HCC (encompassing 51 lesions) was retrospectively included from a prospective parent study (ChiCTR2000039099), and sequential PET/CT using [F]FDG and [Ga]Ga-FAPI-04 was performed.
Brain Res
January 2025
Department of Radiology, Beijing Friendship Hospital, Capital Medical University, No. 95 YongAn Road, Beijing 100050, People's Republic of China. Electronic address:
Brain aging is an inevitable process in adulthood, yet there is a lack of objective measures to accurately assess its extent. This study aims to develop brain age prediction model using magnetic resonance imaging (MRI), which includes structural information of gray matter and integrity information of white matter microstructure. Multiparameter MRI was performed on two population cohorts.
View Article and Find Full Text PDFInt Urol Nephrol
January 2025
Department of Urology, School of Medicine, Shanghai East Hospital, Tongji University, No. 150 Jimo Road, Pudong New District, Shanghai, 200120, China.
Purpose: To evaluate the predictive value of Prostate Spherical Volume Ratio for Lower urinary tract symptoms and clinical progression of Benign prostatic hyperplasia. And compared with other prostatic anatomical parameters.
Methods: A total of 154 patients with Benign prostatic hyperplasia who underwent MRI and urodynamics were included in the study, while prostate anatomical parameters such as prostate spherical volume ratio, prostate volume, intravesical prostatic protrusion, prostatic urethral length and presumed circle area ratio were determined based on MRI measurements.
J Affect Disord
January 2025
Medical Imaging Center, First Affiliated Hospital of Jinan University, Guangzhou 510630, China; Institute of Molecular and Functional Imaging, Jinan University, Guangzhou 510630, China. Electronic address:
Background: The neurobiological mechanisms behind the antidepressant effect of bright light therapy (BLT) are unclear. We aimed to explore the dynamic functional connectivity (dFC) changes of the cingulate cortex (CC) in subthreshold depression (StD).
Methods: The StD participants (38 BLT and 39 placebo) underwent resting-state functional magnetic resonance imaging (rs-fMRI) and mood assessment before and after eight-week BLT.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!