Purpose: Recent studies have shown an excellent correlation between PET/MR and PET/CT hybrid imaging in detecting lesions. However, a systematic underestimation of PET quantification in PET/MR has been observed. This is attributable to two methodological challenges of MR-based attenuation correction (AC): (1) lack of bone information, and (2) truncation of the MR-based AC maps (μmaps) along the patient arms. The aim of this study was to evaluate the impact of improved AC featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR.
Methods: The MR-based Dixon method provides four-compartment μmaps (background air, lungs, fat, soft tissue) which served as a reference for PET/MR AC in this study. A model-based bone atlas provided bone tissue as a fifth compartment, while the HUGE method provided truncation correction. The study population comprised 51 patients with oncological diseases, all of whom underwent a whole-body PET/MR examination. Each whole-body PET dataset was reconstructed four times using standard four-compartment μmaps, five-compartment μmaps, four-compartment μmaps + HUGE, and five-compartment μmaps + HUGE. The SUV for each lesion was measured to assess the impact of each μmap on PET quantification.
Results: All four μmaps in each patient provided robust results for reconstruction of the AC PET data. Overall, SUV was quantified in 99 tumours and lesions. Compared to the reference four-compartment μmap, the mean SUV of all 99 lesions increased by 1.4 ± 2.5% when bone was added, by 2.1 ± 3.5% when HUGE was added, and by 4.4 ± 5.7% when bone + HUGE was added. Larger quantification bias of up to 35% was found for single lesions when bone and truncation correction were added to the μmaps, depending on their individual location in the body.
Conclusion: The novel AC method, featuring a bone model and truncation correction, improved PET quantification in whole-body PET/MR imaging. Short reconstruction times, straightforward reconstruction workflow, and robust AC quality justify further routine clinical application of this method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00259-017-3864-4 | DOI Listing |
Anal Bioanal Chem
January 2025
Biospring Gesellschaft für Biotechnologie, Alt-Fechenheim 34, Frankfurt am Main, 60386, Germany.
The use of single-guide RNA (sgRNA) for gene editing using the CRISPR Cas9 system has become a powerful technique in various fields, especially with the growing interest in such molecules as therapeutic options in the last years. An important parameter for the use of these molecules is the verification of the correct sgRNA oligonucleotide sequence. Apart from next-generation sequencing protocols, mass spectrometry (MS) has been proven as a powerful technique for this purpose.
View Article and Find Full Text PDFWe present both experimental and simulation results for a fully etched, C-band GC fabricated in an 800 nm silicon nitride platform that significantly reduces backreflections. They are minimized by truncating the initial grates, which deflect reflected light at an oblique angle and excite higher-order modes in the tapered waveguide that is filtered out. Insertion losses resulting from this modification of the grating coupler are mitigated by an adaptive redesign of the grates that corrects incurred errors in the generated phase front.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Objective And Rationale: Small studies have shown that the QT interval follows a circadian rhythm. This finding has never been confirmed in a large real-world hospital population and the clinical meaning of disrupted rhythmicity remains unknown.
Methods: In this cohort study, all consecutive adult patients with at least one 12-lead ECG acquired between 1991 and 2021 were considered.
Sensors (Basel)
December 2024
School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
Megavoltage computed tomography (MVCT) plays a crucial role in patient positioning and dose reconstruction during tomotherapy. However, due to the limited scan field of view (sFOV), the entire cross-section of certain patients may not be fully covered, resulting in projection data truncation. Truncation artifacts in MVCT can compromise registration accuracy with the planned kilovoltage computed tomography (KVCT) and hinder subsequent MVCT-based adaptive planning.
View Article and Find Full Text PDFEye Vis (Lond)
January 2025
National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Background: Keratoconus (KC) is a prevalent corneal condition with a modest genetic basis. Recent studies have reported significant genetic associations in multi-ethnic cohorts. However, the situation in the Chinese population remains unknown.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!