The process by which art paintings are produced typically involves the successive applications of preparatory and paint layers to a canvas or other support; however, there is an absence of nondestructive modalities to provide a global mapping of the stratigraphy, information that is crucial for evaluation of its authenticity and attribution, for insights into historical or artist-specific techniques, as well as for conservation. We demonstrate sparsity-based terahertz reflectometry can be applied to extract a detailed 3D mapping of the layer structure of the 17th century easel painting Madonna in Preghiera by the workshop of Giovanni Battista Salvi da Sassoferrato, in which the structure of the canvas support, the ground, imprimatura, underpainting, pictorial, and varnish layers are identified quantitatively. In addition, a hitherto unidentified restoration of the varnish has been found. Our approach unlocks the full promise of terahertz reflectometry to provide a global and detailed account of an easel painting's stratigraphy by exploiting the sparse deconvolution, without which terahertz reflectometry in the past has only provided a meager tool for the characterization of paintings with paint-layer thicknesses smaller than 50 μm. The proposed modality can also be employed across a broad range of applications in nondestructive testing and biomedical imaging.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5678175 | PMC |
http://dx.doi.org/10.1038/s41598-017-15069-2 | DOI Listing |
Vestn Oftalmol
May 2023
Krasnov Research Institute of Eye Diseases, Moscow, Russia.
This article reviews modern functional and instrumental examination methods included in the diagnostic algorithm for dry eye disease. The described methods can serve as an objective criterion for the effectiveness of the therapy.
View Article and Find Full Text PDFIEEE Trans Terahertz Sci Technol
March 2022
Department of Electronics and Nanoengineering, Aalto University, Espoo, FI-02150, Finland.
A system concept for online alignment verification of millimeter-wave, corneal reflectometry is presented. The system utilizes beam scanning to generate magnitude-only reflectivity maps of the cornea at 650 GHz and compares these images to a precomputed/measured template map to confirm/reject sufficient alignment. A system utilizing 5 off-axis parabolic mirrors, a thin film beam splitter, and 2-axis galvanometric mirror was designed, simulated, and evaluated with geometric and physical optics.
View Article and Find Full Text PDFVestn Oftalmol
June 2021
Lomonosov Moscow State University, Moscow, Russia.
Unlabelled: Application of terahertz (THz) radiation in novel non-invasive biomedical technologies has recently received considerable attention. However, experimental data about the safety of exposure to THz radiation for biological objects (including eye structures ) are limited. To our knowledge, the safety of THz reflectometry (frequency range of 0.
View Article and Find Full Text PDFDevelopments toward the implementation of a terahertz pulse imaging system within a guided reflectometry configuration are reported. Two photoconductive antennas patterned on the same LT-GaAs active layer in association with a silica pipe hollow-core waveguide allowed us to obtain a guided optics-free imager. Besides working in a pulsed regime, the setup does not require additional optics to focus and couple the terahertz pulses into the waveguide core, simplifying the global implementation in comparison with other reported guided terahertz reflectometry systems.
View Article and Find Full Text PDFMaterials (Basel)
November 2019
Istituto di Fisica Applicata "Nello Carrara", Consiglio Nazionale delle Ricerche, v. M. del Piano 10, 50019 Sesto Fiorentino (FI), Italy.
Here, a systematic study in order to assess the potential of THz time domain reflectometry for measuring the thicknesses of overpaint layers applied on original gilded surfaces was carried out. The work is part of a thorough characterization campaign, which is going on at the Rijksmuseum for addressing the conservation problems of a set of 19th century gilded picture frames on which heavy coatings were applied in previous undocumented restoration interventions. To perform such non-invasive thickness measurements, an analytical protocol based on Gaussian fits of the THz pulse-echo temporal profiles was optimized through the preparation of suitable technical samples and the comparison with direct thickness measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!