A sensitive and efficient ratiometric electrochemical aptasensor was designed for tetracycline (TET) detection in milk. The ratiometric electrochemical aptasensor was constructed by integrating two aptasensors termed as aptasensor 1 and aptasensor 2. The aptasensor 1 was fabricated that based on ferrocene (Fc) and gold nanoparticles (AuNPs) nanocomposite. Meanwhile, the aptasensor 2 was prepared that based on carbon nanofibers (CNFs) and AuNPs nanocomposite. TET-aptamer was immobilized effectively onto screen-printed carbon electrodes (SPCEs) surface through forming Au-S bond between AuNPs and thiol of aptamer at 5' end to construct the aptasensor 1 and aptasensor 2. And their detection results were calculated by ratio. Thus, the proposed ratiometric aptasensor solved the problem of low accuracy and large differences between batches. Under the optimized conditions, the TET was detected by differential pulse voltammetry (DPV). Taken advantage of ratio calculation, the as-prepared ratiometric aptasensor could detect TET quantitatively in the range of 10-10gL, with a detection limit of 3.3 × 10gL. Moreover, its applicability to TET-contaminated real samples (milk) showed an excellent agreement with the values determined by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-ESI-MS/MS). With high sensitivity, accuracy and reliability, the developed ratiometric aptasensor held a great potential in TET detection for food safety.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5676786 | PMC |
http://dx.doi.org/10.1038/s41598-017-15333-5 | DOI Listing |
Anal Chem
January 2025
School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China.
The outbreak of the monkeypox epidemic underscores the importance of developing a rapid and sensitive virus detection technique. Microneedles (MNs) offer minimally invasive sampling capabilities, providing a solution for the development of integrated extraction and diagnostic portable devices. Here, we report an integrated MNs and hydrogel biosensor (IMHB) platform, composed of an electronic device, an MN patch, and a hydrogel patch.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, School of Medicine, Linyi University, Linyi, China. Electronic address:
MicroRNA (miRNA) serves as an effective and viable biomarker for early diagnosis and monitoring of cancer disorders. It is highly expressed in tumor cells, including lung cancer, liver cancer and lymphoma. Herein, we propose a ratiometric electrochemical sensor for ultrasensitive detection of miRNA-21 using dual signal amplification, hybridization chain reaction and Exo III assisted-amplification.
View Article and Find Full Text PDFChempluschem
January 2025
Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi, 221005 UP, India.
A new conjugate, 2-(4-(anthracen-9-yl) phenyl)-[1,2-d]imidazole-1H-anthraquninone (AQI) has been designed and synthesized as a molecular probe 4. The photophysical and electrochemical behavior of the probe in the absence and presence of different class of ions were examined in acetonitrile solution. The probe 4 with F and CN anions showed ratiometric fluorescence "turn - On" response due to variation in ICT processes.
View Article and Find Full Text PDFJ Hazard Mater
December 2024
Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Jiangxi Provincial Key Laboratory of Tissue Engineering, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou 341000, PR China. Electronic address:
The sensitive detection of Staphylococcus aureus (S. aureus) holds great practical importance for ensuring public health and food safety. In this study, a sensitivity and stability ratiometric electrochemical aptasensor using graphene quantum dots/[Cu (benzotriazole-5-COO) (benzotriazole-5-COOH) (μ-Cl) (μ-OH)-(HO)]·3 HO nanocomposite (GQDs/Cu-MOF) was constructed for S.
View Article and Find Full Text PDFTalanta
April 2025
School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou, 221116, China.
A novel dual-mode electrochemiluminescence (ECL)/photoelectrochemistry (PEC) biosensor was developed for sensitive serotonin detection. In this system, the PEC signal was produced by CdS quantum dots (QDs), while the ECL signal originated from L-Au NPs (luminol decorated Au nanoparticles), thereby avoiding the external interference and signal fluctuations that typically arose from using the same materials for both signals. The presence of target serotonin initiated the non-enzymatic toehold-mediated strand displacement reaction (TSDR) on magnetic bead (MB), which was followed by catalytic hairpin assembly (CHA) on the sensing interface, leading to the aggregation of many L-Au NPs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!