Accuracy of Coracoid Bone Graft Placement: Open versus Arthroscopic Latarjet.

Joints

Research Center of Osteoporosis and Osteoarticular Diseases, University of Genoa, Genoa, Italy.

Published: June 2017

 The aim of this study was to compare the accuracy of the coracoid bone graft placement with the open Latarjet-Patte and arthroscopic Latarjet (arthro-Latarjet) procedures in the treatment of anterior instability of the shoulder.  Forty-six patients affected by anterior shoulder instability were divided into two groups. In group A (  = 25), patients were operated by arthroscopic Latarjet (arthro-Latarjet) procedure and in group B (  = 21), patients were operated by open Latarjet-Patte procedure. Instrumental investigation was based on three-dimensional computed tomography (3D-CT) at a minimum 1-year follow-up. Graft placement and integration, divergence and posterior protrusion of the screws, and glenohumeral osteoarthritis were considered as outcomes. Statistical analysis was performed with chi-square or Fisher's exact test. Significance was set at  < 0.05.  Positioning of the coracoid graft proved to be optimal in 76% (19/25) of patients of group A and in 100% (21/21) of patients of group B (Fisher's exact test,  = 0.025). Screw placement with respect to the glenoid surface showed a posterior divergence in 44% (11/25) of patients in group A and in 24% (5/21) of patients in group B (  = 0.15). Posterior protrusion of screw was observed in 76% (19/25) of patients in group A and 71.4% (15/21) of patients in group B (  = 0.73). Graft integration was present in 76% (19/25) of patients in group A and 85.7% (18/21) of patients in group B (Fisher's exact test,  = 0.48). Mild signs of glenohumeral osteoarthritis were observed in 12% (3/25) of patients in group A and 28.6% (6/21) of patients in group B (Fisher's exact test,  = 0.26).  Patients operated with open Latarjet-Patte procedure showed better results than those of the arthro-Latarjet group in reference to the positioning of the graft on the coronal plane (  = 0.025). No significant differences between the groups were observed for graft integration, divergence of the screws, posterior protrusion of the screws, and osteoarthritis.  Level II, nonrandomized prospective comparative study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5672875PMC
http://dx.doi.org/10.1055/s-0037-1603934DOI Listing

Publication Analysis

Top Keywords

graft placement
12
arthroscopic latarjet
12
accuracy coracoid
8
coracoid bone
8
bone graft
8
placement open
8
open latarjet-patte
8
latarjet arthro-latarjet
8
patients operated
8
open versus
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!