We report a case of two hemiarthroplasties (HAs) that underwent an unexpected mechanical failure. Two patients affected by femoral fractures were treated with an HA. At 5 and 7 years after surgery, they showed a breakage of the HA at the head-stem junction. We analyzed macroscopically and microscopically (by a scanning electron microscopy) the surfaces of the broken prostheses. In both cases, a fracture was detected starting at the joining point between the femoral head and the slot that receives the taper cone of the stem (the so-called bore), with the typical macroscopic and microscopic pattern of a fatigue fracture. The fatigue fracture resulted from repeated cycles of torsional stresses throughout the years. In literature, we did not find any other report of such HA failure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5672855 | PMC |
http://dx.doi.org/10.1055/s-0037-1601407 | DOI Listing |
BMC Oral Health
January 2025
Department of Prosthetic Dentistry, Biomaterials Division, Faculty of Dentistry, King Salman International University, El Tur, South Sinai, Egypt.
Purpose: Investigating high performance thermoplastic polymers as substitutes to titanium alloy, in fabrication of implants and attachments to support mandibular overdenture, aiming to overcome stress shielding effect of titanium alloy implants. AIM OF STUDY: Assessment of stress distribution in polymeric prosthetic components and bone around polymeric implants, in case of implant-supported mandibular overdenture.
Materials And Methods: 3D finite element model was established for mandibular overdenture, supported bilaterally by two implants at canine region, and retained by two ball attachments.
BMC Pregnancy Childbirth
January 2025
Royal Hospital for Women and UNSW, School of Clinical Medicine, Level 0, Royal Hospital for Women, Barker Street (Locked Bag 2000), Sydney, NSW, 2031, Australia.
Background: Congenital heart disease (CHD) is the most common fetal malformation, and it can result first in cardiac remodeling and dysfunction and later in cardiac failure and hydrops. A limited number of studies have evaluated cardiac function in fetuses affected by CHD. Functional parameters could potentially identify fetuses at risk of cardiac failure before its development.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Key Laboratory of Organic Optoelectronics and Molecular Engineering and Laboratory of Flexible Electronics Technology, Department of Chemistry, Tsinghua University, Beijing 100084, P. R. China.
Wearable temperature-sensitive electronic skin enables robots to rapidly detect environmental changes and respond intelligently, thereby reducing temperature-related mechanical failures. Additionally, this temperature-sensitive skin can measure and record the temperature of external objects, broadening its potential applications in the medical field. In this study, we designed a thermally sensitive artificial ionic skin using ionic liquids (ILs) as solvents and carbon nanotubes (CNTs) as thermally conductive fillers.
View Article and Find Full Text PDFASAIO J
January 2025
From the Division of Cardiac Surgery, Department of Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
The use of cardiac devices, including mechanical circulatory support (MCS), cardiac implantable electronic devices (CIEDs), and pacing wires, has increased and significantly improved survival in patients with severe cardiac failure. However, these devices are frequently associated with acute brain injuries (ABIs) including ischemic strokes, intracranial hemorrhages, seizures, and hypoxic-ischemic brain injury which contribute substantially to morbidity and mortality. Computed tomography (CT) and magnetic resonance imaging (MRI), the standard imaging modalities for ABI diagnosis, can pose significant challenges in this patient population due to the risks associated with patient transportation and the incompatibility of ferromagnetic components of certain cardiac devices with high magnetic field of the MRI.
View Article and Find Full Text PDFCardiol Rev
January 2025
Departments of Cardiology and Medicine, New York Medical College and Westchester Medical Center, Valhalla, NY.
Right ventricular myocardial infarction (RVMI) is a significant and distinct form of acute myocardial infarction associated with considerable morbidity and mortality. It occurs most commonly due to proximal right coronary artery obstruction, often in conjunction with inferior myocardial infarction. RVMI poses unique diagnostic and therapeutic challenges due to the anatomical and functional differences between the right and left ventricles.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!