A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical Comparison of I-Gel Supraglottic Airway Device and Cuffed Endotracheal Tube for Pressure-Controlled Ventilation During Routine Surgical Procedures. | LitMetric

Objective: Recently, there has been a trend favouring the use of supraglottic airway devices over endotracheal tubes (ETT) during short surgical procedures. In this study, we are going to assess the suitability of one such supraglottic airway device, i-gel, for pressure-controlled ventilation (PCV) during routine surgical procedures.

Methods: The airway management for 60 patients was done with either i-gel (Group I) or cuffed tracheal tube (Group E) for this prospective, randomised, double-blinded study. Insertion time, number of attempts, ease of insertion and haemodynamic monitoring were recorded before, during and after insertion of these devices. Airway leak tests, leak volume and leak fraction were measured at 15, 20 and 25 cm HO PCV, and pharyngolaryngeal morbidity was evaluated postoperatively.

Results: I-gel is easier to insert than a tracheal tube (p=0.0056). The increase in heart rate and MAP was higher following insertion of tracheal tube in the first few minutes (p<0.001) and subsequently became comparable between the two groups. The leak volume and leak fraction between the two groups were comparable at 15 cm HO PCV, but significant difference was seen at 20 and 25 HO PCV between the two groups (p=0.232, p<0.001, p<0.001). Thirty minutes later, the leak volume and leak fraction between groups were comparable at 15 cm HO PCV (p=0.495, p=0.104) but not at 20 and 25 HO PCV (p<0.001, p<0.001). Pharyngolaryngeal morbidity was significantly lesser in the i-gel group.

Conclusion: I-gel provides a reasonable alternative to cuffed ETT for pressure-controlled ventilation provided the pressures can be limited to 15 to 20 cm HO.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5656161PMC
http://dx.doi.org/10.5152/TJAR.2017.44711DOI Listing

Publication Analysis

Top Keywords

supraglottic airway
12
tracheal tube
12
airway device
8
pressure-controlled ventilation
8
routine surgical
8
surgical procedures
8
airway
5
clinical comparison
4
i-gel
4
comparison i-gel
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!