Objective: Bioelectrical impedance vectorial analysis (BIVA) can be considered a favorable method for evaluation and monitoring of nutritional and hydration status without assumptions regarding body composition or requirement of prediction formulas. The present study aimed to determine bivariate tolerance intervals of the whole-body impedance vector for healthy term infants aged 1 to 3 months.

Methods: This is a descriptive cross-sectional study. Anthropometric and bioelectrical impedance data (800 mA-50 kHz) were obtained. Bivariate vector analysis was conducted with the resistance-reactance (RXc) graph method. BIVA software was used to construct the graphs.

Results: A total of 150 appropriate for gestational age infants (48.7% boys) who were exclusively breastfed and were 56.4 (SD = 23.1) days of age were studied. RXc tolerance ellipses (50, 75, and 95%) were constructed for boys and girls, but a general reference graph was defined for all infants considering the overlapping of ellipses between the genders. All graphs differed from those in national and foreign studies.

Conclusion: New reference tolerance ellipses (95, 75, and 50%) for 1- to 3-month-old infants were constructed, pointing out the need for specific reference values of total body impedance vectors in different regions of Brazil. The RXc tolerance ellipses can be used for clinical practice and provide an easy method to evaluate and monitor body composition and hydration status.

Download full-text PDF

Source
http://dx.doi.org/10.1080/07315724.2017.1364678DOI Listing

Publication Analysis

Top Keywords

bioelectrical impedance
12
tolerance ellipses
12
impedance vector
8
vector analysis
8
healthy term
8
term infants
8
hydration status
8
body composition
8
rxc tolerance
8
infants
5

Similar Publications

Background: Acute and critical neurological diseases are often accompanied with elevated intracranial pressure (ICP), leading to insufficient cerebral perfusion, which may cause severe secondary lesion. Existing ICP monitoring techniques often fail to effectively meet the demand for real-time noninvasive ICP monitoring and warning. This study aimed to explore the use of electrical impedance tomography (EIT) to provide real-time early warning of elevated ICP by observing cerebral perfusion.

View Article and Find Full Text PDF

Background: Although little is yet known about the long-term maintenance of very low-energy ketogenic therapy (VLEKT) effects on body composition, muscle strength and inflammation, it is plausible to assume that changes may occur, particularly during the steps following the ketogenic step, due to the loss of the protective effects of ketones and the concomitant reintroduction of carbohydrates. For this reason, the present study aimed to evaluate the effects of supplementation with 8 g per day of essential amino acids (EAAs) on these parameters.

Methods: A total of 68 women of reproductive age and with grade I obesity who had completed 45 days of the ketogenic phase with VLEKT (KeNuT protocol) and 40 days of non-ketogenic phase of KeNuT protocol with VLEKT (phase 3, fruit reintroduction) were included in the study.

View Article and Find Full Text PDF

Integration of Asymmetric Multi-Path Hollow Structure and Multiple Heterogeneous Interfaces in FeO@C@NiO Nanoprisms Enabling Ultra-Low and Broadband Absorption.

Small

January 2025

Key Laboratory of Aerospace Materials and Performance (Ministry of Education) School of Materials Science and Engineering, Beihang University, No.37 Xueyuan Road, Beijing, 100191, P. R. China.

A reasonable construction of hollow structures to obtain high-performance absorbers is widely studied, but it is still a challenge to select suitable materials to improve the low-frequency attenuation performance. Here, the FeO@C@NiO nanoprisms with unique tip shapes, asymmetric multi-path hollow cavity, and core-shell heteroepitaxy structure are designed and synthesized based on anisotropy and intrinsic physical characteristics. Impressively, by changing the load of NiO, the composites achieve strong absorption, broadband, low-frequency absorption: the reflection loss of -55.

View Article and Find Full Text PDF

Assessing muscle mass in critically ill patients remains challenging. This retrospective cohort study explores the potential of phase angle (PA°) derived from bioelectrical impedance analysis (BIA) as a surrogate marker for muscle mass monitoring by associating it with daily creatinine excretion (DCE), a structural and metabolic muscle mass marker. In 20 ICU patients, we observed a linear relationship between PA° and DCE at initial (S1) and follow-up (S2) points, with Rho values of 0.

View Article and Find Full Text PDF

This study aimed to examine potential changes in the anthropometric and motor characteristics of volleyball players aged 17.98 ± 0.51 years after participation in a week-long sports camp.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!