A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical validation of automatic local activation time annotation during focal premature ventricular complex ablation procedures. | LitMetric

Aims: Current navigation systems incorporate algorithms for automatic identification of local activation time (LAT). However, data about their utility and accuracy in premature ventricular complex (PVC) ablation procedures are scarce. This study analyses the accuracy of an algorithmic method based on automatic annotation of the maximal negative slope of the unipolar electrogram within the window demarcated by the bipolar electrogram compared with conventional manual annotation during PVC ablation procedures.

Methods And Results: Forty patients with successful ablation of focal PVC in three centres were included. Electroanatomical activation maps obtained with the automatic system (WF-map) were compared with manual annotation maps (M-map). Correlation and concordance of LAT obtained with both methods were assessed at 3536 points. The distance between the earliest activation site (EAS) and the effective radiofrequency application point (e-RFp) were determined in M-map and WF-map. The distance between WF-EAS and M-EAS was assessed. Successful ablation sites included left ventricular outflow tract (LVOT; 55%), right ventricular outflow tract (40%), and tricuspid annulus (5%). Good correlation was observed between the two annotation approaches (r = 0.655; P < 0.0001). Bland-Altman analysis revealed a systematic delayed detection of LAT by WF-map (bias 33.8 ± 30.9 ms), being higher in LVOT than in the right ventricle (42.6 ± 29.2 vs. 27.2 ± 30.5 ms, respectively; P < 0.0001). No difference in EAS-eRFp distance was observed between M-map and WF-map (1.8 ± 2.8 vs. 1.8 ± 3.4 mm, respectively; P = 0.986). The median (interquartile range) distance between WF-EAS and M-EAS was 2.2(0-6) mm.

Conclusion: Good correlation was found between M-map and WF-map. Local activation time detection was systematically delayed in WF-map, especially in LVOT. Accurate identification of e-RFp was achieved with both annotation approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eux306DOI Listing

Publication Analysis

Top Keywords

local activation
8
activation time
8
premature ventricular
8
ventricular complex
8
ablation procedures
8
pvc ablation
8
manual annotation
8
successful ablation
8
ventricular outflow
8
outflow tract
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!