Aims: Catheter ablation is underutilized in atrial septal defect (ASD) patients who have undergone implantation of an atrial septal occluder (ASO). This study evaluates the feasibility and safety of catheter ablation of atrial fibrillation (AF) in this subset of patients.

Methods And Results: Sixteen patients (age 56 ± 12 years, 10 men) with drug-refractory AF (10 paroxysmal and 6 persistent) and previously implanted ASO were enrolled. Balloon dilatation of the closure device was performed if the native septum passage could not be achieved. For paroxysmal AF, the ablation strategy was circumferential pulmonary vein isolation (CPVI), and for persistent AF, additional linear ablation was performed. Transseptal access was achieved through the native septum in 11 patients (Group A) and through the ASO using balloon dilatation in 5 patients (Group B). Circumferential pulmonary vein isolation was achieved in all 16 patients, and linear block was achieved in all persistent patients except for 1 patient who did not achieve mitral isthmus block. The transseptal, total fluoroscopy, and procedural durations were 5 ± 3 vs. 38 ± 8 min, 31 ± 11 vs. 54 ± 15 min, and 165 ± 35 vs. 224 ± 36 min, respectively, in Group A vs. Group B, respectively (all P < 0.05). No shunt at atrial level was detected by transthoracic echocardiography at 3-month follow-up. During a follow-up of 16 ± 6 months, sinus rhythm was maintained in 12 of 16 patients. No severe complications were observed.

Conclusion: In ASD patients with ASO, catheter ablation of AF is feasible, safe, and effective. The balloon dilatation technique can facilitate transseptal access through the ASO.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eux282DOI Listing

Publication Analysis

Top Keywords

catheter ablation
12
atrial septal
12
ablation atrial
8
atrial fibrillation
8
septal occluder
8
balloon dilatation
8
native septum
8
circumferential pulmonary
8
pulmonary vein
8
vein isolation
8

Similar Publications

More and more patients with atrial fibrillation are undergoing catheter ablation as a rhythm-control strategy, but the recurrence rate after the procedure is high. A wide array of risk factors contribute to the pathogenesis of atrial fibrillation, including hypertension, diabetes mellitus, dyslipidemia, obesity, obstructive sleep apnea, metabolic dysfunction-associated steatotic liver disease (MASLD), smoking, alcohol consumption, and physical inactivity. This review summarizes the emerging evidence for periablation risk-factor modification to optimize postablation outcomes.

View Article and Find Full Text PDF

Incidence, Characteristics and Prognostic Significance of Early Recurrences Following Different Ablation Approaches for Persistent Atrial Fibrillation.

Heart Rhythm

December 2024

University of Melbourne, Melbourne, Victoria, Australia; Royal Melbourne Hospital, Melbourne, Victoria, Australia; Baker Heart and Diabetes Research Institute, Melbourne, Victoria, Australia. Electronic address:

Background: Early recurrence of atrial tachyarrhythmia (ERAT) is common following catheter ablation of atrial fibrillation (AF). The specific clinical and arrhythmia characteristics of ERAT influencing late recurrence risk in persistent AF is unclear. Additionally, the impact of different ablation strategies on the incidence and prognostic significance of ERAT remains unknown.

View Article and Find Full Text PDF

12 lead surface ECGs as a surrogate of atrial electrical remodeling - a deep learning based approach.

J Electrocardiol

December 2024

Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA; Alliance for Cardiovascular Diagnostic and Treatment Innovation, Johns Hopkins University, Baltimore, MD, USA.

Background And Purpose: Atrial fibrillation (AF), a common arrhythmia, is linked with atrial electrical and structural changes, notably low voltage areas (LVAs) which are associated with poor ablation outcomes and increased thromboembolic risk. This study aims to evaluate the efficacy of a deep learning model applied to 12‑lead ECGs for non-invasively predicting the presence of LVAs, potentially guiding pre-ablation strategies and improving patient outcomes.

Methods: A retrospective analysis was conducted on 204 AF patients, who underwent catheter ablation.

View Article and Find Full Text PDF

Pulmonary vein anatomical variations are frequently observed in atrial fibrillation patients undergoing catheter ablation. However, when it comes to patients with atrial fibrillation and bilateral common ostium in the inferior pulmonary veins, using a bilateral circumferential pulmonary vein isolation approach during catheter ablation heightens the risk of esophageal injury. At present, there is no established standard catheter ablation strategy for such cases.

View Article and Find Full Text PDF