Objectives: We sought to assess angiographic, echocardiographic and hemodynamic grading of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) with respect to prediction of 1-year mortality.

Background: Meaningful criteria for the severity of PVL are needed to allow intraprocedural guidance and patient management after TAVI.

Methods: We pooled the prospective TAVI databases of 2 German centers. During TAVI, PVL was assessed angiographically and by the aortic regurgitation index (ARI). ARI was calculated as ratio of the gradient between diastolic blood pressure and left ventricular end-diastolic pressure to systolic blood pressure times hundred. In addition, we performed transthoracic echocardiography before discharge.

Results: A total of 723 patients undergoing TAVI with self-expandable (20.9%) or balloon-expandable (79.1%) valves were included. Grades of PVL as assessed during the procedure by angiography or ARI (below the previously defined cut-off of 25) did not show a significant association with 1-year mortality (P = 0.312 and 0.776, respectively). One-year mortality was 15.7% (39/249) in patienths with an ARI < 25 and 16.5% (71/430) in patients with an ARI ≥ 25. Echocardiographic classes of PVL at discharge showed a significant (P = 0.029) association with 1-year mortality, which was 11.5% (37/322) in patients with no/trace PVL, 18.0% (62/345) in patients with mild PVL and 23.1% (6/26) in patients with more than mild PVL. These findings prevailed after multivariable adjustment.

Conclusions: ARI did not help identify PVLs that are relevant to 1-year survival. Angiographic assessment during the procedure was less predictive than echocardiographic assessment before discharge.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.27384DOI Listing

Publication Analysis

Top Keywords

paravalvular leakage
8
transcatheter aortic
8
aortic valve
8
valve implantation
8
angiographic echocardiographic
8
prediction 1-year
8
1-year mortality
8
pvl assessed
8
blood pressure
8
hemodynamic classification
4

Similar Publications

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.

Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.

View Article and Find Full Text PDF

Background: Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce.

View Article and Find Full Text PDF
Article Synopsis
  • Transcatheter aortic valve replacement (TAVR) is a key treatment for severe aortic stenosis, widely considered superior to traditional surgical methods.
  • Despite its benefits, TAVR carries risks, particularly cerebrovascular complications, which can arise from debris embolization and other procedural factors.
  • The review highlights the importance of understanding these complications, discussing their incidence, prevention strategies, and how to improve patient outcomes through better techniques.
View Article and Find Full Text PDF

Background: Takayasu arteritis is a large-vessel vasculitis, in addition to giant cell arteritis. Various post-operative complications associated with the cardiac macrovasculature have been reported. Detachment of the prosthetic valve, pseudoaneurysm formation, and dilatation of the aortic root are well-known post-operative complications associated with vasculitis syndromes, including Takayasu arteritis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!