In this latex immunoassay for human placental lactogen, microtiter plates are used as the reaction vessel and the absorbance at 405 nm is measured to quantify the reactions. This 30-min assay necessitates only one serum dilution and two pipetting steps. The calibration curve extends from 0.5 to 15 mg/L. CVs range from 4.2% to 7.0% for within-run determination and from 7.0% to 11.2% for between-run determinations. A correlation coefficient of 0.949 was obtained for 84 sera when the method was compared with a commercial radioimmunoassay.

Download full-text PDF

Source

Publication Analysis

Top Keywords

latex immunoassay
8
placental lactogen
8
lactogen microtiter
8
microtiter plates
8
turbidimetric latex
4
immunoassay placental
4
plates latex
4
immunoassay human
4
human placental
4
plates reaction
4

Similar Publications

Introduction: Serum cystatin C (CysC) is used to estimate glomerular filtration rate (eGFR), including in the Chronic Kidney Disease in Children (CKiD) Under 25 years (U25eGFR) equations. Several CysC measurement procedures available from diagnostic vendors include reference material for calibration, but the extent of heterogeneity across manufacturers is unclear. Since heterogeneity may have clinical and research implications for eGFR, we evaluated three CysC procedures in samples from the CKiD study representing a wide spectrum of kidney function.

View Article and Find Full Text PDF

Objectives: To describe a variant hemoglobin that interferes with HbA analysis by cation exchange HPLC.

Case Presentation: A 78 years-old Spanish male patient visited the Internal Medicine Clinic for a routine check-up, with HbA included to screen for diabetes. He had suffered hypertension and dyslipidemia, and the patient had no previous symptoms suggestive of diabetes such as hyperglycemia, weight loss, polydipsia, polyuria or tiredness.

View Article and Find Full Text PDF
Article Synopsis
  • Zoonotic schistosomiasis, specifically caused by Schistosoma japonicum, is a significant health issue in countries like China, the Philippines, and Indonesia, highlighting the need for effective diagnostic tools to aid control strategies.
  • The study evaluated five recombinant antigens for diagnostic use, ultimately developing a latex microsphere lateral flow immunoassay (LFIA) with promising results: a sensitivity of 80.6% and specificity of 98.0% in diagnosing schistosomiasis japonica.
  • The LFIA demonstrated superior prevalence detection compared to traditional methods, revealing a higher prevalence of schistosomiasis in the tested population, indicating its potential as a rapid point-of-care diagnostic tool.
View Article and Find Full Text PDF

The fecal calprotectin (f-Cal) test is a convenient method used for differentiating inflammatory bowel disease (IBD) from functional bowel disorders. The OC-Sensor Pledia (OC-FCa; Eiken Chemical Co., Tokyo, Japan) is a latex agglutination turbidimetric immunoassay used for f-Cal measurements.

View Article and Find Full Text PDF

Immunochromatographic Lateral Flow Assays to Detect Filovirus Nucleoproteins.

Methods Mol Biol

November 2024

Division of Global Epidemiology, International Institute for Zoonosis Control, Hokkaido University, Sapporo, Japan.

The recent large outbreaks of Ebola virus disease in West Africa and the Democratic Republic of the Congo have highlighted the need for rapid diagnostic tests to control this disease. In this chapter, the development of immunochromatographic lateral flow assays to detect filovirus nucleoproteins is described as an example of designing rapid diagnostic tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!