Computational fluid dynamics evaluation of excessive dynamic airway collapse.

Clin Biomech (Bristol)

Pulmonary Division, Long Beach Veterans Administration (LBVA) Hospital, 5901 E 7th St, Long Beach, CA 90822, USA. Electronic address:

Published: December 2017

Background: Excessive dynamic airway collapse, which is often caused by the collapse of the posterior membrane wall during exhalation, is often misdiagnosed with other diseases; stents can provide support for the collapsing airways. The standard pulmonary function tests do not necessarily show change in functional breathing condition for evaluation of these type of diseases.

Methods: Flow characteristics through a patient's airways with excessive dynamic airway collapse have been numerically investigated. A stent was placed to support the collapsing airway and to improve breathing conditions. Computed tomography images of the patient's pre- and post-stenting were used for generating 3-Dimensional models of the airways, and were imported into a computational fluid dynamics software for simulation of realistic air flow behavior. Unsteady simulations of the inspiratory phase and expiratory phase were performed with patient-specific boundary conditions for pre- and post-intervention cases to investigate the effect of stent placement on flow characteristic and possible improvements.

Findings: Results of post-stent condition show reduced pressure, velocity magnitude and wall shear stress during expiration. The variation in wall shear stress, velocity magnitude and pressure drop is negligible during inspiration.

Interpretation: Although Spirometry tests do not show significant improvements, computational fluid dynamics results show significant improvements in pre- and post-treatment results, suggesting improvement in breathing condition.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2017.10.018DOI Listing

Publication Analysis

Top Keywords

computational fluid
12
fluid dynamics
12
excessive dynamic
12
dynamic airway
12
airway collapse
12
support collapsing
8
breathing condition
8
velocity magnitude
8
wall shear
8
shear stress
8

Similar Publications

Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development.

Cardiovasc Eng Technol

January 2025

Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.

Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.

View Article and Find Full Text PDF

Simulating fish autonomous swimming behaviours using deep reinforcement learning based on Kolmogorov-Arnold Networks.

Bioinspir Biomim

January 2025

Chongqing Jiaotong University, No. 66, Xuefu Avenue, Nanan District, Chongqing City, Chongqing, Chongqing, 400074, CHINA.

The study of fish swimming behaviours and locomotion mechanisms holds significant scientific and engineering value. With the rapid advancements in artificial intelligence, a new method combining deep reinforcement learning (DRL) with computational fluid dynamics (CFD) has emerged and been applied to simulate the autonomous behavior of higher organisms like fish. However, the scale of this cross-disciplinary method is directly affected by the efficiency of the DRL model.

View Article and Find Full Text PDF

Fluid shear stress (FSS) from blood flow sensed by vascular endothelial cells (ECs) determines vessel behavior, but regulatory mechanisms are only partially understood. We used cell state transition assessment and regulation (cSTAR), a powerful computational method, to elucidate EC transcriptomic states under low shear stress (LSS), physiological shear stress (PSS), high shear stress (HSS), and oscillatory shear stress (OSS) that induce vessel inward remodeling, stabilization, outward remodeling, or disease susceptibility, respectively. Combined with a publicly available database on EC transcriptomic responses to drug treatments, this approach inferred a regulatory network controlling EC states and made several notable predictions.

View Article and Find Full Text PDF

Research on hydrodynamic performance of S-type turbine based on linear wave.

PLoS One

January 2025

Faculty of Mechanical Engineering & Mechanics, Ningbo University, Ningbo, Zhengjiang, China.

The hydrodynamic performance of a Savonius type turbine (S-type turbine) in wave field is studied. The method of combining numerical simulation with physical experiment is adopted.Based on linear wave theory and turbulence model, Star CCM+numerical simulation software is used for digital modeling, and overlapping grid technology is used for grid modeling.

View Article and Find Full Text PDF

Purpose: Idiopathic pulmonary fibrosis (IPF) is a chronic, progressive fibrotic lung disorder characterized by dry cough, fatigue, and exacerbated dyspnea. The prognosis of IPF is notably unfavorable, becoming extremely poor when the disease advances acutely. Effective therapeutic intervention is essential to mitigate disease progression; hence, early diagnosis and treatment are paramount.

View Article and Find Full Text PDF