A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A highly sensitive VEGF photoelectrochemical biosensor fabricated by assembly of aptamer bridged DNA networks. | LitMetric

A highly sensitive VEGF photoelectrochemical biosensor fabricated by assembly of aptamer bridged DNA networks.

Biosens Bioelectron

Education Ministry Key Laboratory on Luminescence and Real-Time Analysis, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, People's Republic of China. Electronic address:

Published: March 2018

We developed a novel "signal-off" photoelectrochemical (PEC) aptasensor based on an aptamer bridged DNA network structure for the sensitive detection of vascular endothelial growth factor (VEGF), using g-CN as photoactive material. The DNA network provides an excellent platform for the immobilization of methylene blue (MB), which can facilitate the electron transport through the DNA helix structure and suppress the recombination of electron-hole pairs generated by g-CN. In the presence of the target VEGF, the DNA network can be destroyed adequately by the recognition between VEGF and the aptamer, resulting in the release of MB. Therefore, the originally enhanced electron transfer process could be inhibited, leading to a remarkable decrease of the photocurrent. A good linear relationship between the PEC signal and the logarithm of VEGF concentration over the range of 100fM to 10nM with a detection limit of 30 fM can be obtained. Our concept can be easily extended to develop aptasensors for the sensitive detection of different targets by triggering the release of the payloads from their corresponding aptamer bridged DNA networks.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2017.10.032DOI Listing

Publication Analysis

Top Keywords

aptamer bridged
12
bridged dna
12
dna network
12
dna networks
8
sensitive detection
8
dna
6
vegf
5
highly sensitive
4
sensitive vegf
4
vegf photoelectrochemical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!