A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Precise Engineering of Conductive Pathway by Frictional Direct-Writing for Ultrasensitive Flexible Strain Sensors. | LitMetric

Precise Engineering of Conductive Pathway by Frictional Direct-Writing for Ultrasensitive Flexible Strain Sensors.

ACS Appl Mater Interfaces

School of Optical and Electronic Information and ‡Innovation Institute, Huazhong University of Science and Technology, 1037 Luoyu Road, 430074 Wuhan, China.

Published: November 2017

Highly sensitive strain sensors that can detect small strain are in high demand in the fields of displays, robotics, fatigue detection, body monitoring, in vitro diagnostics, and advanced therapies. However, resistive-type sensors that are composed of electrically conductive sensing films coupled with flexible substrates suffer from the limits that their gauge factors (GFs) at small strains (e.g., 0.1-1%) are not high. Herein, through frictional direct-writing of graphite rod on the composite paper substrates, we produced strain sensors with extremely high gauge factor at small strains. The sensors exhibited a gauge factor of 9720 at a small strain of 0.9%, minimum strain detection up to 0.05%, strain resolution of 0.05%, response time of 40 ms, and high stability (>5000 bending-unbending cycles). Compared with the literature results so far, our sensors hold the highest GF value at small strains. Such high sensitivities are due to the precise control of narrow two-dimensional percolative conductive pathway, which means the content of conductive graphite sheets is close to the conductive percolation threshold. The strain sensors have a rapid response to microdeformation changes and can monitor various structural changes, including human motion, through facilitative and effective installation of device designs.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.7b14501DOI Listing

Publication Analysis

Top Keywords

strain sensors
16
small strains
12
conductive pathway
8
frictional direct-writing
8
strain
8
small strain
8
gauge factor
8
sensors
7
conductive
5
small
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!