A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modulation properties enhancement in a monolithic integrated two-section DFB laser utilizing side-mode injection locking method. | LitMetric

A monolithic optical injection-locked (MOIL) DFB laser with large stable injection locking range is experimentally demonstrated using the side-mode injection locking technique. The low-frequency roll-off in the MOIL DFB laser is suppressed significantly. The relaxation oscillation frequency is measured to be 26.84 GHz and the intrinsic 3-dB response bandwidth is more than 30 GHz, which is about 20 GHz higher than that of the free running DFB laser. The nonlinear distortions, including the 1-dB compression point, second harmonic distortion (2HD) and third-order intermodulation distortion (IMD3), are also suppressed significantly. A simple radio-over-fiber system transmitting 40 Msymbol/s 32-QAM signal with 6 GHz carrier is achieved using the MOIL DFB laser. After 50 km transmission, the average error vector magnitude (EVM) of the whole link is 2.94% in injection locked state, while the EVM in free running DFB laser is 5.25% as a comparison. To our knowledge, this is the first time that the MOIL DFB laser is realized utilizing the side-mode injection locking method.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.25.027595DOI Listing

Publication Analysis

Top Keywords

dfb laser
28
injection locking
16
moil dfb
16
side-mode injection
12
utilizing side-mode
8
locking method
8
free running
8
running dfb
8
dfb
7
laser
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!