Quantitative dual-energy radiographic absorptiometry (DRA) and dual-photon absorptiometry (DPA) were compared to determine the best means of assessing bone density. Both methods were used to evaluate the lumbar spine in 107 women (aged 35-84 years [mean, 64 years]) referred for evaluation of osteoporosis risk. High correlation was documented between measurements derived by the two techniques, with a .95 linear regression coefficient for the total spine density measurement. Age-related regression equations were similar in slope but manifested different intercepts. Bone mineral density values derived with DRA were consistently lower than those obtained with DPA (conversion equation: DPA density = [1.067 X DRA density] + 0.163). Besides the inherent imperfections of each system, it was found that inaccurate identification of intervertebral spaces on the low-resolution DPA images introduced errors in patient data. DRA may replace DPA as the dedicated projectional densitometric procedure of choice for technical reasons, but at present a conversion equation must be used to compare DRA data to DPA data.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.170.1.2909085DOI Listing

Publication Analysis

Top Keywords

quantitative dual-energy
8
dual-energy radiographic
8
radiographic absorptiometry
8
lumbar spine
8
dual-photon absorptiometry
8
conversion equation
8
dpa
6
dra
5
absorptiometry
4
absorptiometry lumbar
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!