The laser-based transmitter used in this Letter is composed of an integrated optical Mach-Zehnder interferometer, which was first used in fault diagnosis. With the help of the effective signal processing method and laser-based integrated optical Mach-Zehnder (IOMZ) system, the location of the defect in an aluminum plate can be successfully determined. Moreover, a comparison study is conducted to investigate the effectiveness of both the conventional laser spot source and the IOMZ interferometer-based laser source. The results indicate that the IOMZ interferometer-based method can be very useful to the nondestructive testing research field. The potential for industrial applications is also significant, especially for the health monitoring and integrity inspection of metal plates.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.42.004255DOI Listing

Publication Analysis

Top Keywords

integrated optical
12
optical mach-zehnder
12
iomz interferometer-based
8
mach-zehnder interferometer-based
4
interferometer-based defect
4
defect detection
4
detection laser-generated
4
laser-generated ultrasonic
4
ultrasonic guided
4
guided wave
4

Similar Publications

Van der Waals (vdWs) materials are promising candidates for hetero-integration with silicon photonics toward miniaturization and integration. VdWs materials like molybdenum telluride and black phosphorus, despite being prominent, exhibit air sensitivity, and their room temperature emissions can be significantly broadened by tens of meV. Here, a self-encapsulation strategy is developed to scalably synthesize robust 2D vdWs ErOCl with sub-meV narrow emissions at the telecom C-band.

View Article and Find Full Text PDF

Background: This study aimed to explore behaviour of practitioners in response to the COVID-19 pandemic, analysing the factors that influenced their decisions to resume professional practice post-lockdown and intention to adhere to COVID-19 protective measures.

Methods: A web-based cross-sectional survey targeting Italian practitioners was carried out to study the post lockdown behaviour and future intention to provide new contact lens (CL) fittings, and the use of protective measures. The survey also explored the dimensions of the Integrated Behavioural Model (IBM) and the Health Belief Model (HBM) to predict the intention to resume professional practice and to comply with protective measures respectively.

View Article and Find Full Text PDF

Kerr microresonators generate interesting and useful fundamental states of electromagnetic radiation through nonlinear interactions of continuous-wave (CW) laser light. With photonic-integration techniques, functional devices with low noise, small size, low-power consumption, scalable fabrication, and heterogeneous combinations of photonics and electronics can be realized. Kerr solitons, which stably circulate in a Kerr microresonator, have emerged as a source of coherent, ultrafast pulse trains and ultra-broadband optical-frequency combs.

View Article and Find Full Text PDF

Fully phase-stabilized 1 GHz turnkey frequency comb at 1.56 μm.

OSA Contin

January 2020

Time and Frequency Division, NIST, 325 Broadway, Boulder, Colorado 80305, USA.

Low noise and high repetition rate optical frequency combs are desirable for many applications, from timekeeping to precision spectroscopy. For example, gigahertz repetition rate sources greatly increase the acquisition speed of spectra in a dual-comb modality when compared to lower repetition rate sources, while still maintaining sufficient instantaneous resolution to resolve ro-vibrational signatures from molecules in a variety of conditions. In this paper, we present the stabilization and characterization of a turnkey commercial 1 GHz mode-locked laser that operates at telecom wavelengths (1.

View Article and Find Full Text PDF

A novel balloon-type photoacoustic cell (BTPAC) is proposed to facilitate the detection limitations of acetylene (CH) gas achieving ppb level. Here, an ellipsoidal photoacoustic cavity is employed as the platform for gas-light interaction. By strategically directing the excitation source towards the focal point of the ellipsoidal cavity, ensuring its trajectory traverses the focal point upon each reflection from the interior walls.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!