Aim: To identify predictors of need for repeat procedures after initial atrial fibrillation (AF) ablation.

Methods: We identified a cohort undergoing first time AF ablation at our institution from January 2004 to February 2014 who had cardiac magnetic resonance (CMR) imaging performed prior to ablation. Clinical variables and anatomic characteristics (determined from CMR) were assessed as predictors of need for repeat ablation. The decision regarding need for and timing of repeat ablation was at the discretion of the treating physician.

Results: From a cohort of 331 patients, 142 patients (43%) underwent repeat ablation at a mean of 13.6 ± 18.4 mo after the index procedure. Both male gender (81% 71%, = 0.05) and lower ejection fraction (57.4% ± 10.3% 59.8% ± 9.4%, = 0.04) were associated with need for repeat ablation. On pre-ablation CMR, mean pulmonary vein (PV) diameters were significantly larger in all four PVs among patients requiring repeat procedures. In multivariate analysis, increased right superior PV diameter significantly predicted need for repeat ablation (odds ratio 1.08 per millimeter increase in diameter, 95%CI: 1.00-1.16, = 0.05). There were also trends toward significance for increased left and right inferior PV sizes among those requiring repeat procedures.

Conclusion: Increased PV size predicts the need for repeat AF ablation, with each millimeter increase in PV diameter associated with an approximately 5%-10% increased risk of requiring repeat procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5633538PMC
http://dx.doi.org/10.4330/wjc.v9.i9.742DOI Listing

Publication Analysis

Top Keywords

repeat ablation
24
predictors repeat
12
repeat procedures
12
requiring repeat
12
repeat
11
ablation
9
atrial fibrillation
8
millimeter increase
8
increase diameter
8
clinical anatomic
4

Similar Publications

Duodromic atrioventricular reentry tachycardia: a case report of a rare adenosine insensitive supraventricular tachycardia.

Eur Heart J Case Rep

January 2025

Arrhythmology, Pacing and Electrophysiology Unit, Cardiology Service, Santa Marta Hospital, Central Lisbon Hospital University Centre, R. de Santa Marta 50, Lisboa 1169-024, Portugal.

Background: Accessory pathways (AP) are associated with an increased risk of atrioventricular reentry tachycardia (AVRT), presenting as a wide QRS tachycardia if the mechanism is antidromic. Rarely, AVRT may not respond to adenosine, suggesting a duodromic mechanism if the patient has multiple APs. Herein, we present a case of a male patient with multiple APs, wide QRS complex tachycardia, and resistance to adenosine.

View Article and Find Full Text PDF

Introduction: A hybrid approach with very high-power short-duration (vHPSD) posteriorly and ablation-index guided HPSD (50 W) anteriorly seems to be an optimal balance between efficiency and effectiveness for point-by-point pulmonary vein isolation (PVI). The aim of the current study is to compare vHPSD/HPSD ablation to cryoballoon ablation (CBA) in patients with symptomatic atrial fibrillation (AF).

Methods And Results: In this retrospective single-center study, we identified 110 consecutive patients who underwent their first PVI with either vHPSD/HPSD (n = 54) or CBA (n = 56).

View Article and Find Full Text PDF

A 75-year-old female presented with fasting hypoglycemic episodes. A supervised fast ended at 72 hours fulfilling Whipple triad, with suppressed insulin and C-peptide levels, but discordantly suppressed serum β-hydroxybutyrate levels. After 21 months of recurring symptoms, a repeat fast ended at 48 hours with Whipple triad, suppressed serum β-hydroxybutyrate level, and borderline nonsuppressed C-peptide level, suggesting endogenous hyperinsulinism.

View Article and Find Full Text PDF

Purpose: To optimize the effectiveness and safety of pulmonary vein isolation, pulsed-field ablation (PFA) and high-power short-duration ablation (HPSD) have recently been incorporated into clinical practice. The objective of this study is to conduct a comparative analysis, focusing on the efficacy, safety, and procedural efficiency of PFA and HPSD in the treatment of atrial fibrillation (AF).

Methods: A thorough search was performed across multiple databases to identify trials that compared PFA with HPSD for AF from their inception until July 2024.

View Article and Find Full Text PDF

There is limited available data regarding the impact of cycle length (CL) prolongation when converting atrial fibrillation (AF) to organized atrial tachycardia (AT) and its effect on clinical outcomes. We retrospectively screened and included a cohort of 132 patients with persistent or long-standing persistent AF who underwent circumferential pulmonary vein isolation (CPVI) and left atrial substrate modification (LASM) between January 2015 and October 2019. In all 132 consecutive patients, persistent AF was successfully converted into organized AT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!