High gamma band (>50 Hz) activity is a key oscillatory phenomenon of brain activation. However, there has not been a non-invasive method established to detect language-related high gamma band activity. We used a 160-channel whole-head magnetoencephalography (MEG) system equipped with superconducting quantum interference device (SQUID) gradiometers to non-invasively investigate neuromagnetic activities during silent reading and verb generation tasks in 15 healthy participants. Individual data were divided into alpha (8-13 Hz), beta (13-25 Hz), low gamma (25-50 Hz), and high gamma (50-100 Hz) bands and analysed with the beamformer method. The time window was consecutively moved. Group analysis was performed to delineate common areas of brain activation. In the verb generation task, transient power increases in the high gamma band appeared in the left middle frontal gyrus (MFG) at the 550-750 ms post-stimulus window. We set a virtual sensor on the left MFG for time-frequency analysis, and high gamma event-related synchronization (ERS) induced by a verb generation task was demonstrated at 650 ms. In contrast, ERS in the high gamma band was not detected in the silent reading task. Thus, our study successfully non-invasively measured language-related prefrontal high gamma band activity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5660237 | PMC |
http://dx.doi.org/10.1038/s41598-017-14452-3 | DOI Listing |
Biosci Biotechnol Biochem
January 2025
Graduate School of Agricultural Science, Tohoku University, Miyagi, Japan.
This study developed water-dispersible γ-oryzanol (WD-OZ) using microemulsion system and assessed their absorption in rats. While γ-oryzanol itself is hardly soluble in water, WD-OZ exhibited high water dispersibility, and γ-oryzanol, along with its metabolites, was detected in rat plasma. These findings provide a solid basis for future application of the microemulsion-based approach to enhance the bioavailability of γ-oryzanol in food.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
College of Food Science and Engineering, Henan University of Technology, Zhengzhou, Henan Province, PR China. Electronic address:
The aim of this study was to investigate the mechanism of protein digestibility improvement by exploring the changes in structural characteristics of proteins in noodles with varying levels of mechanically activated starch. Therefore, different levels of mechanically activated wheat starch were mixed with refined wheat flour to produce noodles. Results showed that moderately mechanically activated starch could significantly improve protein digestibility and noodles containing 8.
View Article and Find Full Text PDFArq Bras Cir Dig
January 2025
Santa Casa de Misericórdia de Porto Alegre - Porto Alegre (RS), Brazil.
Background: Cholangiocarcinoma (CCA) is a rare neoplasm, with high mortality, originating in the bile ducts. Its incidence is higher in Eastern countries due to the endemic prevalence of liver parasites. Factors such as metabolic syndrome, smoking, and pro-inflammatory conditions are also linked to the disease.
View Article and Find Full Text PDFVasc Biol
January 2025
J van Buul, Medical Biochemistry, Amsterdam UMC Locatie AMC, Amsterdam, 1105 AZ, Netherlands.
Objective: Donor liver preservation methods and solutions have evolved over the last years. Liver sinusoidal endothelial cell (LSEC) barrier function and integrity during preservation is crucial for outcomes of liver transplantation. Therefore, the present study aimed to determine optimal preservation of LSEC barrier function and integrity, using different preservation solutions.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Radiation Oncology, Stanford University, Palo Alto, California, USA.
Background: Dosimetric commissioning and quality assurance (QA) for linear accelerators (LINACs) present a significant challenge for clinical physicists due to the high measurement workload and stringent precision standards. This challenge is exacerbated for radiosurgery LINACs because of increased measurement uncertainty and more demanding setup accuracy for small-field beams. Optimizing physicists' effort during beam measurements while ensuring the quality of the measured data is crucial for clinical efficiency and patient safety.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!