Unlabelled: Current physical activity (PA) recommendations for women experiencing a normal pregnancy reflect recent research showing numerous health benefits for mother and offspring. However, few studies have evaluated PA devices' reliability and validity during pregnancy, because anatomical and physiological changes throughout gestation could affect an instrument's accuracy.
Purpose: This study aimed to determine the reliability and validity of PA devices worn on the hip, ankle, and triceps during pregnancy and postpartum.
Methods: Thirty-three women performed six activities of daily living and one treadmill walk at approximately 21 and 32 wk of pregnancy, and 12 wk postpartum. There were two visits at each time period, 1 wk apart. Energy expenditure (oxygen consumption) was measured by using indirect calorimetry (IC; criterion measure), whereas PA was quantified by using accelerometers and pedometers placed at the right hip and ankle and left triceps. Interclass reliability and monitor validity compared with IC in relative (mL·kg·min) terms were calculated using Pearson correlation. Both multitrial and single-trial intraclass reliabilities (ICC) were estimated using ANOVA to assess monitor reliability at each time period. SEM values were calculated in relative terms for each time period.
Results: The reliability of the devices was moderate/strong because 66% of the Pearson correlations were between 0.6 and 1.0. Multitrial ICC values were largely in the moderate/strong range because 38% of the ICC values were between 0.6 and 0.79 and 50% were between 0.8 and 1.0. The SEM values for each device between visits ranged from 7% to 23% of the mean values. Comparison between IC and devices showed that 40% and 46% of the validity coefficients were between 0.4 and 0.59 and between 0.6 and 0.79, respectively.
Conclusions: PA devices show moderate/strong reliability and moderate validity for measuring PA during pregnancy and postpartum.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1249/MSS.0000000000001469 | DOI Listing |
Chin Med
January 2025
State Key Laboratory of Natural Medicines, School of Traditional Chinese Pharmacy, China Pharmaceutical University, No. 639 Longmian Road, Nanjing, 211198, China.
Background: Cell membrane chromatography (CMC) is a biochromatography with a dual function of recognition and separation, offering a distinct advantage in screening bioactive compounds from Chinese medicines (CMs). Yindan Xinnaotong soft capsule (YD), a CM formulation, has been widely utilized in the treatment of cardiovascular disease. However, a comprehensive mapping of the myocardial protective active compounds remains elusive.
View Article and Find Full Text PDFJ Sci Med Sport
December 2024
Faculty of Education, University of the Ryukyus, Japan.
Objectives: To examine the validity and reliability of the Simple Motor Competence-check for Kids (SMC-Kids), which was developed to assess motor development in preschool children.
Design: A cross-sectional and repeated-measures design.
Methods: To assess validity, 71 children aged 4-6 years completed the Test of Gross Motor Development-3 (TGMD-3) and SMC-Kids (10 m shuttle run and paper ball throw).
Am J Clin Nutr
January 2025
School of Epidemiology and Public Health, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada; Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada.
Background: Although high-quality nutrition systematic reviews (SRs) are important for clinical decision making, there remains debate on their methodological quality and reporting transparency.
Objectives: The objective of this study was to assess the reliability and reproducibility of a sample of SRs produced by the Nutrition Evidence Systematic Review (NESR) team to inform the 2020-2025 Dietary Guidelines for Americans (DGAs).
Methods: We evaluated a sample of 8 SRs from the DGA dietary patterns subcommittee for methodological quality using the Assessment of Multiple Systematic Reviews 2 (AMSTAR 2) tool and for reporting transparency using the PRISMA 2020 and PRISMA literature search extension (PRISMA-S) checklists.
Body Image
January 2025
School of Psychology, University of Sheffield, Sheffield S1 4DP, United Kingdom.
Research demonstrates that self-objectification negatively impacts both cisgender heterosexual women and men. However, measures of self-objectification have primarily been designed for and validated in women, raising doubts about their applicability to men and demonstrated gender differences in self-objectification. This research investigated the psychometric properties of the Self-Objectification Beliefs and Behaviors Scale (SOBBS; Lindner & Tantleff-Dunn, 2017) in cisgender heterosexual women, and for the first time, in cisgender heterosexual men.
View Article and Find Full Text PDFBreast
January 2025
Department of Plastic Surgery, Copenhagen University Hospital, Herlev and Gentofte, Denmark; Department of Clinical Medicine, University of Copenhagen, Denmark.
Aim/background: Patient-reported outcome measurement instruments are important tools in understanding a breast reconstruction's impact on the patients' quality of life. A psychometric validation is essential before applying a patient-reported outcome measurement instrument in clinical practice and research. The BREAST-Q is a specific, validated questionnaire for breast surgery outcomes that has been translated from English to Danish.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!