Background: We sought to develop a standardized protocol for ultrasound (US) measurements of plantar fascia (PF) width and cross-sectional area (CSA), which may serve as additional outcome variables during US examinations of both healthy asymptomatic PF and in plantar fasciopathy and determine its interrater and intrarater reliability.
Methods: Ten healthy individuals (20 feet) were enrolled. Participants were assessed twice by two raters each to determine intrarater and interrater reliability. For each foot, three transverse scans of the central bundle of the PF were taken at its insertion at the medial calcaneal tubercle, identified in real time on the plantar surface of the foot, using a fine wire technique. Reliability was determined using intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and limits of agreement (LOA) expressed as percentages of the mean. Reliability of PF width and CSA measurements was determined using PF width and CSA measurements from one sonogram measured once and the mean of three measurements from three sonograms each measured once.
Results: Ultrasound measurements of PF width and CSA showed a mean of 18.6 ± 2.0 mm and 69.20 ± 13.6 mm respectively. Intra-reliability within both raters showed an ICC > 0.84 for width and ICC > 0.92 for CSA as well as a SEM% and LOA% < 10% for both width and CSA. Inter-rater reliability showed an ICC of 0.82 for width and 0.87 for CSA as well as a SEM% and LOA% < 10% for width and a SEM% < 10% and LOA% < 20% for CSA. Relative and absolute reliability within and between raters were higher when using the mean of three sonographs compared to one sonograph.
Conclusions: Using this novel technique, PF CSA and width may be determined reliably using measurements from one sonogram or the mean of three sonograms. Measurement of PF CSA and width in addition to already established thickness and echogenicity measurements provides additional information on structural properties of the PF for clinicians and researchers in healthy and pathologic PF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7547/16-042 | DOI Listing |
Zhonghua Kou Qiang Yi Xue Za Zhi
January 2025
Department of Orthodontics, Stomatological Hospital of Chongqing Medical University & Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences & Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, China.
To explore the changes of atlantoaxial joint spaces and pharyngeal airway after combined orthodontic-orthognathic treatment in skeletal class Ⅲ patients with mandibular deviation. A total of 34 adult skeletal class Ⅲ patients (10 males and 24 females) with mandibular deviation who received combined orthodontic-orthognathic treatment at the Department of Orthodontics and the Department of Orthognathic Surgery in the Stomatological Hospital of Chongqing Medical University from August 2014 to October 2021 were retrospectively selected. The patients were 22 (5) years old (18-33 years).
View Article and Find Full Text PDFOrthop J Sports Med
January 2025
Department of Orthopaedics and Traumatology, Faculty of Medicine, Tınaztepe University, Izmir, Turkey.
Background: Magnetic resonance imaging (MRI) measurement parameters-the standard noninvasive diagnostic method for rotator cuff tears (RCTs)-have been used to compare groups with and without RCTs. Arthroscopy is used in definitive diagnosis and treatment.
Purposes: To evaluate the association between RCT and shoulder angles and distances on MRI in patients with and without arthroscopically validated RCT and to determine whether the degree of rotator cuff fatty degeneration affects the MRI measurements.
Introduction: Cataract surgery has been reported to have a reducing effect on intraocular pressure (IOP) in glaucomatous and non-glaucomatous eyes. This effect seems to be more noticeable in eyes with narrow angles (NAs) than in eyes with open angles (OAs). Decrease in IOP may be a result of the increase in anterior chamber angle (ACA) and Schlemm canal (SC) after cataract surgery.
View Article and Find Full Text PDFAsian Spine J
December 2024
Department of Radiology, Advantage Imaging and Research Institute, Chennai, India.
Study Design: Matched case-control study.
Purpose: To evaluate the midterm outcomes of unilateral pedicle screw fixation (UPSF) versus bilateral pedicle screw fixation (BPSF) in transforaminal lumbar interbody fusion (TLIF) procedure, ascertain efficacy of UPSF in adequately decompressing contralateral foramen+spinal canal and reducing rate of adjacent segment degeneration (ASD) at 4-8-year follow-up (FU).
Overview Of Literature: Previous meta-analyses found no significant differences between UPSF and BPSF regarding fusion rates, clinical and radiological outcomes; however, few studies have reported higher rates of cage migration/subsidence and pseudoarthrosis in the UPSF.
Int J Concr Struct Mater
December 2024
Civil and Architectural Engineering Department, University of Miami, Coral Gables, FL 33146 USA.
The current provisions for development length in the ACI 440.11 code disregard the confinement effect provided by stirrups on the bond strength of longitudinal bars and require splice lengths that pose implementation challenges. Given the significant improvement in GFRP material properties, this study investigated the bond strength of sand-coated GFRP bars and proposed a new factor to include the effect of stirrup confinement on the bond-strength provisions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!