Minimizing open-loop piezoactuator nonlinearity artifacts in atomic force microscope measurements.

J Vac Sci Technol B Nanotechnol Microelectron

Department of Physics and Astronomy, Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011.

Published: September 2017

Atomic force microscopes (AFMs) are widely used to study molecular interactions with piconewton force sensitivity. In an AFM, interaction forces are measured by reflecting a laser beam off a cantilever onto a position sensitive detector and monitoring cantilever deflection. Precise measurements of interaction forces rely on accurately determining the optical lever sensitivity, i.e., the relationship between cantilever deflection and changes in detector voltage. The optical lever sensitivity is measured by pressing the cantilever against a hard substrate using a piezoactuator and recording the resulting change in detector voltage. However, nonlinearities in the motion of commonly used open-loop piezo actuators introduce significant errors in measured optical lever sensitivities. Here, the authors systematically characterize the effect of piezo actuator hysteresis and creep on errors in optical lever sensitivity and identify measurement conditions that minimize these errors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5648552PMC
http://dx.doi.org/10.1116/1.4994315DOI Listing

Publication Analysis

Top Keywords

optical lever
16
lever sensitivity
12
atomic force
8
interaction forces
8
cantilever deflection
8
detector voltage
8
minimizing open-loop
4
open-loop piezoactuator
4
piezoactuator nonlinearity
4
nonlinearity artifacts
4

Similar Publications

Self-induced optical non-reciprocity.

Light Sci Appl

January 2025

CAS Key Laboratory of Quantum Information & CAS Center For Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei, 230026, China.

Non-reciprocal optical components are indispensable in optical applications, and their realization without any magnetic field has attracted increasing research interest in photonics. Exciting experimental progress has been achieved by either introducing spatial-temporal modulation of the optical medium or combining Kerr-type optical nonlinearity with spatial asymmetry in photonic structures. However, extra driving fields are required for the first approach, while the isolation of noise and the transmission of the signal cannot be simultaneously achieved for the other approach.

View Article and Find Full Text PDF
Article Synopsis
  • Spintronic terahertz emitters (STEs) are powerful terahertz sources that can operate across a wide range of pumping frequencies, yet their performance is ultimately limited by their optical damage threshold.
  • Recent advancements in technology require STEs to pump at higher megahertz rates rather than the traditional kilohertz rates, highlighting a gap in research on this topic.
  • The study introduces a new classification of the optical damage threshold based on repetition rates and identifies temperature-driven inter-layer diffusion as the main failure cause, offering insights for improving STE performance in future applications.
View Article and Find Full Text PDF

A novel nucleic acid extraction system integrating a switching valve-assisted microfluidic cartridge and a constant pressure pump.

Anal Chim Acta

November 2024

Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China. Electronic address:

Background: Nucleic acid extraction (NAE) is essential in molecular diagnostics, genetic engineering, and DNA sequencing. While advances in switching valve-assisted, self-contained microfluidic (SM) cartridges have improved the NAE processes, challenges persist in streamlining workflows, reducing processing times, and enhancing multi-target detection. Achieving these objectives requires precise control of on-chip fluid dynamics and efficient transfer of nucleic acid solutions (NAS) to detection areas.

View Article and Find Full Text PDF

Humans and non-humans alike often make choices to gain information, even when the information cannot be used to change the outcome. Prior research has shown the anterior cingulate cortex (ACC) is important for evaluating options involving reward-predictive information. Here we studied the role of ACC in information choices using optical inhibition to evaluate the contribution of this region during specific epochs of decision making.

View Article and Find Full Text PDF

Object lifting is often categorized into squat and stoop techniques, with the former believed to protect the back by maintaining a neutral spine, and the latter considered harmful due to spinal flexion. Despite the widespread promotion of these beliefs, there is no evidence to support such dichotomy, as spinal flexion is not conclusively linked to low back pain. This study aimed to investigate intervertebral disc deformation in the lower lumbar spine during squat and stoop lifting using indwelling bone pins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!