The ability to control high-intensity focused ultrasound (HIFU) thermal ablation using echo decorrelation imaging feedback was evaluated in ex vivo bovine liver. Sonications were automatically ceased when the minimum cumulative echo decorrelation within the region of interest exceeded an ablation control threshold, determined from preliminary experiments as -2.7 (log-scaled decorrelation per millisecond), corresponding to 90% specificity for local ablation prediction. Controlled HIFU thermal ablation experiments were compared with uncontrolled experiments employing two, five or nine sonication cycles. Means and standard errors of the lesion width, area and depth, as well as receiver operating characteristic curves testing ablation prediction performance, were computed for each group. Controlled trials exhibited significantly smaller average lesion area, width and treatment time than five-cycle or nine-cycle uncontrolled trials and also had significantly greater prediction capability than two-cycle uncontrolled trials. These results suggest echo decorrelation imaging is an effective approach to real-time HIFU ablation control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5712268PMC
http://dx.doi.org/10.1016/j.ultrasmedbio.2017.09.007DOI Listing

Publication Analysis

Top Keywords

echo decorrelation
16
thermal ablation
12
decorrelation imaging
12
control high-intensity
8
high-intensity focused
8
focused ultrasound
8
ablation echo
8
vivo bovine
8
bovine liver
8
hifu thermal
8

Similar Publications

For very high frequency (VHF) phased array radar, the key problem to be solved in altitude measurement is the super-resolution spatial spectrum estimation under the condition of coherent sources. The spatial smoothing algorithm is a kind of decorrelation algorithm with excellent properties, but the decorrelation process is at the expense of the effective array aperture. Because it only uses the autocorrelation information of the subspace, its performance is significantly reduced, when the positions of the coherent sources are very close.

View Article and Find Full Text PDF

Multiexciton quintet state populations in a rigid pyrene-bridged parallel tetracene dimer.

Chem Sci

October 2023

National Renewable Energy Laboratory 15013 Denver West Parkway Golden Colorado 80401 USA

The multiexciton quintet state, TT, generated as a singlet fission intermediate in pairs of molecular chromophores, is a promising candidate as a qubit or qudit in future quantum information science schemes. In this work, we synthesize a pyrene-bridged parallel tetracene dimer, TPT, with an optimized interchromophore coupling strength to prevent the dissociation of TT to two decorrelated triplet (T) states, which would contaminate the spin-state mixture. Long-lived and strongly spin-polarized pure TT state population is observed transient absorption spectroscopy and transient/pulsed electron paramagnetic resonance spectroscopy, and its lifetime is estimated to be >35 µs, with the dephasing time () for the TT-based qubit measured to be 726 ns at 10 K.

View Article and Find Full Text PDF

The Effect of Spatial Velocity Gradients on Block-Matching Accuracy for Ultrasound Velocimetry.

Ultrasound Med Biol

January 2024

Department of Biomedical Engineering, Thorax Center, Erasmus Medical Center, Rotterdam, The Netherlands.

Objective: Block matching serves as the foundation for ultrasound velocimetry techniques such as blood speckle tracking and echo-particle image velocimetry. Any spatial velocity gradients (SVGs) inside a block-matching pair will result in tracking error, due to both the finite block size and the ultrasound point-spread-function. We assess, using an in silico sinusoidal flow phantom, the effect of SVG magnitude and beam-to-flow angle on block-matching bias and precision.

View Article and Find Full Text PDF

Decorrelated compounding of synthetic aperture ultrasound imaging to detect low contrast thermal lesions induced by focused ultrasound.

Ultrasonics

September 2023

Department of Physics, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario, Canada; Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital, Toronto, Ontario, Canada. Electronic address:

Purpose: Decorrelated Compounding (DC) for synthetic aperture ultrasound can reduce speckle variation in images, suggesting enhanced detectability of low-contrast targets in tissue including thermal lesions produced by focused ultrasound (FUS). The DC imaging method has primarily been investigated in simulation and in phantom studies. This work investigates the feasibility of the DC method in monitoring thermal therapy via image guidance and non-invasive thermometry based on the change in backscattered energy (CBE).

View Article and Find Full Text PDF

Three-dimensional (3D) echo decorrelation imaging was investigated for monitoring radiofrequency ablation (RFA) in ex vivo bovine liver. RFA experiments (N = 14) were imaged by 3D ultrasound using a matrix array, with in-phase and quadrature complex echo volumes acquired about every 11 s. Tissue specimens were then frozen at -80 °C, sectioned, and semi-automatically segmented.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!