A novel hybrid cooling vest (HCV) incorporated with phase change materials (PCMs) and ventilation fans has been developed for construction workers in Hong Kong to attenuate heat stress and prevent heat-related illnesses, and its effectiveness and practicality have been validated in this study. A total of 140 wear trials involving of 140 workers were conducted in Hong Kong construction sites during the summer time. Each wear trial involves a two-day wear test, of which one day workers wore the HCV (denoted as VEST) during resting, and another day they wore traditional workwear (denoted as CON). Subjects were asked to rate their perceived exertion (RPE), thermal sensations (TS) and 7 other subjective attributes. There were significant differences in the effectiveness on reducing workers' heat strain between VEST and CON in terms of alleviations of heart rate (ΔHR), ΔTS, ΔRPE as well as ΔPeSI (p < 0.001). The practicality of HCV is evidenced by a significant improvement by 0.93-1.34 on the rating scores of perceived cooling effect, sensations of comfort and skin dryness during rest and fatigue recovery in VEST at the level of 0.05, and high ratings of 4.85-5 (rating scale from 1 to 7, and the higher the better) by subjects on the preference, fitness as well as effectiveness to combat heat stress. In addition, a remarkable proportion of 91 per cent of subjects prefer to use this newly designed HCV as a cooling measure during rest. The power to alleviate perceptual heat stain (PeSA) in VEST is about twice of that by rest, which means HCV can notably improve the workers' perceptual heat strain in a limited resting duration. However, the strain alleviation power of HCV nearly remains unchanged with the prolonged rest duration. Thus, the optimal work-rest schedule needs to be investigated in a further study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtherbio.2017.07.012DOI Listing

Publication Analysis

Top Keywords

hong kong
12
effectiveness practicality
8
novel hybrid
8
cooling vest
8
kong construction
8
heat stress
8
heat strain
8
perceptual heat
8
vest
6
hcv
6

Similar Publications

An adequate understanding of the NO interacting chemistry is a prerequisite for a smoother transition to carbon-lean and carbon-free fuels such as ammonia and hydrogen. In this regard, this study presents a comprehensive study on the H atom abstraction by NO from C to C alkynes, dienes, and trienes forming 3 HNO isomers (i.e.

View Article and Find Full Text PDF

Health lifestyles in China reflect complex interplays of various structural forces, yielding intricate and evolving patterns. Leveraging data from the 2004-2015 China Health and Nutrition Survey ( = 9,986), this study discerns latent health lifestyles, tracks transitional dynamics, and probes socioeconomic disparities in these shifts. Three distinct lifestyle categories emerge: 'high risk', 'overall healthy but inactive', and 'modernized and active'.

View Article and Find Full Text PDF

The effectiveness of loss-framed versus gain-framed messages in attracting attention and influencing purchase intention among younger and older adults remains unclear. We tracked the eye movements of 92 younger (18-39 years) and 83 older adults (60-82 years) while they viewed 32 advertisements and reported their purchase intentions for each advertised product. The results showed that loss-framed (vs.

View Article and Find Full Text PDF

Artifacts at Cardiac MRI: Imaging Appearances and Solutions.

Radiographics

January 2025

From the Department of Radiology, Cardiovascular Imaging, Mayo Clinic, 200 1st St SW, Rochester, MN 559905 (P.S.R., P.A.A.); Department of Radiology, Division of Cardiothoracic Imaging, Jefferson University Hospitals, Philadelphia, Pa (B.S.); Department of Radiology, Baylor Health System, Dallas, Tex (P.R.); Department of Diagnostic Radiology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong SAR (M.Y.N.); and Department of Diagnostic Radiology, Cleveland Clinic, Cleveland, Ohio (M.A.B.).

Cardiac MRI (CMR) is an important imaging modality in the evaluation of cardiovascular diseases. CMR image acquisition is technically challenging, which in some circumstances is associated with artifacts, both general as well as sequence specific. Recognizing imaging artifacts, understanding their causes, and applying effective approaches for artifact mitigation are critical for successful CMR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!