Purpose: To study the effect of torsional phacoemulsification energy on corneal endothelium evaluating the relationship between changes of endothelial cells and postoperative visual acuity.

Methods: This prospective clinical observational cohort study included 50 patients with cataract who underwent torsional phacoemulsification. Sequential quantitative and qualitative morphometric endothelial cell analyses of the cornea were performed four weeks preoperatively and six weeks postoperatively using noncontact specular microscopy.

Results: This work confirmed the strong relationship, described by a linear model (one-way ANOVA, R2 = 77.9%, P < 0.0001), between the percentage of endothelial cell loss (ECL%) and the 5-score harm scale. According to the Tukey post-hoc pairwise comparison test, distinct values of ECL% are grouped in 3 subsets. The value of ECL = 10% has been identified as cut-off to discriminate patients with excellent postoperative best-corrected visual acuity (BCVA > 85 letters) from those with just a good/satisfied visual outcome (BCVA ≤ 85 letters). Within the 5-score harm scale, there was a significant correlation among phaco energy intraoperatively delivered and the average endothelial cell loss.

Conclusions: This study confirms the validity of the 5-score harm scale first proposed by Sorrentino and colleagues in 2016. This time, the method categorizes cataracts taking into account nucleus hardness and phaco cumulative dissipated energy. Predicting the harm on corneal endothelium, we can discriminate patients with excellent BCVA and with just good/satisfied BCVA. With torsional phacoemulsification with respect to longitudinal, the percentage of patients who can reach excellent BCVA is remarkably increased.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5658130PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0186975PLOS

Publication Analysis

Top Keywords

torsional phacoemulsification
16
endothelial cell
12
5-score harm
12
harm scale
12
visual acuity
8
corneal endothelium
8
discriminate patients
8
patients excellent
8
excellent bcva
8
endothelial
5

Similar Publications

Purpose: This study aimed to determine the rate of retained metallic intraocular foreign bodies (IOFBs) following torsional phacoemulsification cataract surgery by an experienced surgeon and elucidate related surgical factors, particle origin theories from existing literature, and postoperative visual impact.

Methods: An observational study was conducted on 300 consecutive cases of cataract who underwent torsional phacoemulsification by a single surgeon using two-handed stop-and-chop technique. The incidence of retained IOFBs was observed and correlated with the surgical parameters and the density of cataract.

View Article and Find Full Text PDF

Purpose: To compare the efficiencies of the Active Sentry handpiece at low IOP (20 mmHg) to the Ozil handpiece at high IOP (50 mmHg).

Setting: Private practice (Medford, OR, USA).

Design: Single site, prospective, double-arm, randomized, contralateral eye study.

View Article and Find Full Text PDF

Purpose: To evaluate the efficiency of a hybrid tip in removing cataract grade 3 and 4 in high and low intraocular pressure (IOP) settings.

Methods: This was a randomized, prospective, double-arm contralateral eye study. One randomized eye of each subject had phacoemulsification with high IOP settings (50 mmHg) while the other eye had phacoemulsification with low IOP settings (20 mmHg).

View Article and Find Full Text PDF
Article Synopsis
  • Phacoemulsification is the main technique for cataract surgery but can lead to severe complications if lens nuclei are dislodged, traditionally managed through a method that risks retinal damage.
  • This study evaluated the OZil phacoemulsification handpiece, which uses torsional movement, to see if it could reduce surgical time and complications compared to the standard phacofragmatome.
  • Results showed that the OZil handpiece significantly shortened surgery duration and decreased the occurrence of nucleus dislocation while maintaining similar postoperative outcomes for vision and safety as the traditional method.*
View Article and Find Full Text PDF

Purpose: This study aims to investigate the differences between the heat energy produced during cataract surgery and Cumulative dissipated energy (CDE). CDE is often used as a medium for understanding the energy delivered to the eye during cataract surgery. However, the actual energy produced at the tip level of the tip is not well understood.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!