Background: Serum biomarkers, such as serum creatinine (SCr) and serum cystatin C (SCysC), have been widely used to evaluate renal function in patients who have chronic kidney disease (CKD).

Objective: This article aims to assess the value of determining SCr and SCysC levels in patients that have long-term kidney disease. Approaches: MEDLINE, EmBase, the Cochrane Library and other databases were searched using both MeSH terms and text words to collect research that assessed the diagnostic value of using SCr and SCysC to evaluate Glomerular Filtration Rate (GFR) in patients with CKD. Data were converted into fourfold tables. Summary Receiver Operating Characteristic Curves and meta-analyses were accomplished via Meta-Disc version 1.4.

Results: In total, 21 relevant articles involving 3112 study subjects were included in our review. Results showed that the collective sensitivity for SCr and SCysC was 0.77 (95% CI: 0.69-0.84) and 0.87 (95% CI: 0.82-0.91), respectively. The pooled specificity for SCr and SCysC was 0.91 (95% CI: 0.86-0.94) and 0.87 (95% CI: 0.82-0.91), respectively. Subgroup analyses demonstrated that when GFR cut-off values are set to 60 (ml/min/1.73 m), the pooled sensitivity is 0.94 (95% CI: 0.90-0.96) for SCysC and 0.75 (95% CI: 0.68-0.82) for SCr.

Conclusions: The diagnostical accuracy for impaired kidney function favors SCysC. Confidence intervals for the pooled sensitivity and specificity for SCr and SCysC overlap. However, SCysC is more sensitive for estimating GFR than SCr when GFR cut-off values are set to 60 (ml/min/1.73 m).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5641185PMC
http://dx.doi.org/10.18632/oncotarget.20271DOI Listing

Publication Analysis

Top Keywords

scr scysc
20
kidney disease
12
scysc
9
serum creatinine
8
glomerular filtration
8
filtration rate
8
patients chronic
8
chronic kidney
8
scysc evaluate
8
087 95%
8

Similar Publications

Very few studies worldwide have assessed the estimated glomerular filtration rate (eGFR) using serum cystatin C (ScysC) in comparison to the gold standard measured glomerular filtration rate (mGFR) with a gamma camera technique using 99m-Technetium-Diethylene Triaminepentoacetic Acid (99mTc-DTPA). To determine the eGFR formula with the most accurate estimate of glomerular filtration rate when compared with mGFR in a healthy population in Vietnam. We conducted a cross-sectional descriptive study of more than 100 adults without hypertension.

View Article and Find Full Text PDF
Article Synopsis
  • - The study was a scoping review following PRISMA guidelines, aimed at evaluating literature on urinary and renal system monitoring in people with spinal cord injuries (SCI), focusing on methods of surveillance and risk factors for urinary tract abnormalities.
  • - 685 studies were initially reviewed, with findings indicating that serum cystatin C (s-cysC) is a reliable measure for glomerular filtration rate, while adherence to surveillance does not significantly impact the development of urinary tract abnormalities over time.
  • - The research concludes that s-cysC is preferable to serum creatinine for kidney function assessment and suggests targeted surveillance strategies based on individual risk profiles for better patient care.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the effectiveness of seven different formulas for estimating glomerular filtration rate (GFR) in children with acute lymphoblastic leukemia (ALL) undergoing high-dose methotrexate (HDMTX) chemotherapy, focusing on a GFR cutoff of 85 ml/min.
  • A total of 124 children with ALL were examined, using renal dynamic imaging (sGFR) as the standard for comparison of the estimated GFR (eGFR) values calculated by the seven formulas.
  • The results indicated that the Schwartz2009 formula provided the highest accuracy across various age groups, while CKD-EPI, Filler, and Cockrofi-Gault formulas also showed significant reliability for HDMTX dose
View Article and Find Full Text PDF

2-Methyl-4-chlorophenoxyacetic acid (MCPA) is a widely used chlorophenoxy herbicide. MCPA poisoning causes mitochondrial dysfunction, which can lead to kidney injury and death. The objective of this study is to describe the epidemiology, case fatality and extent of renal injury in a large cohort of MCPA self-poisonings.

View Article and Find Full Text PDF

To compare the applicability of 14 equations of estimating glomerular filtration rate (eGFR) before and after nephron-sparing surgery (NSS) for renal function assessment of patients with renal tumors. Preoperative and postoperative GFR is measured by emission computed tomography (ECT) with 99mTc-DTPA as an imaging agent as reference GFR (rGFR) to compare with all formulas. Spearman correlation analysis and Bland-Altman agreement analysis were used to evaluate the correlation between rGFR and eGFR1 to 14 before and after surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!